Chamberlain LA400UL Wiring Diagram
Chamberlain LA400UL Wiring Diagram

Chamberlain LA400UL Wiring Diagram

Hide thumbs Also See for LA400UL:

Advertisement

Available languages

Available languages

Quick Links

To reduce the risk of INJURY or DEATH:
• DISCONNECT power and battery BEFORE installing or servicing operator.
• Replace ONLY with fuse of same type and rating.
• To be compliant with UL325 and industry safety guidelines, qualified monitored
external entrapment protection devices such as photoelectric sensors or edge
sensors are required to be installed with this operator at each entrapment zone.
Use ONLY LiftMaster approved entrapment protection devices (refer to the
accessory page of manual).
• See manual prior to servicing regarding maintenance and required safety testing.
Diagnostic Codes
TO VIEW THE CODES:
Press and hold
...then press and
...then press and hold OPEN
STOP...
hold CLOSE...
until "Er" shows.
The operator will show the code sequence number followed by the code number:
A SECOND LATER....
CODE SEQUENCE NUMBER
CODE NUMBER
The first number shown is the most
The second number shown after the code
recent code (example: "01"). The
sequence number is the code itself
display will show the sequence of
(31-99, example" "31").
codes that occurred starting with "01"
and going up to code "20".
TO SCROLL THROUGH THE SAVED CODES:
Press the OPEN button to cycle to the most recent code ("01"). Press the CLOSE button
to cycle to the oldest code (up to "20").
CODE COLOR KEY:
LiftMaster System
External Entrapment Protection
Installed System
Inherent Entrapment Protection
Informational
CODE MEANING
SOLUTION
Main control board has experienced an internal
Disconnect all power, wait 15 seconds, then
31
failure.
reconnect power (reboot). If issue continues,
replace main control board.
32
Linear Drive Disengaged (Arm 1)
Disengage then re-engage arm. Check wiring and
connections.
33
Linear Drive Disengaged (Arm 2)
Max-Run-Time Exceeded Error
Check for an obstruction, then reprogram the
35
limits.
Product ID Error
Was the control board just replaced? If so, erase
limits, enter limit setup mode and set limits. If
36
not, disconnect all power, wait 15 seconds, then
reconnect power before changing product ID
harness.
Product ID Failure
Unplug product ID harness then plug back in.
Disconnect all power, wait 15 seconds, then
37
reconnect power before replacing product ID
harness.
38
Hard Stop Limit (Arm 1)
Limit may be set too tightly against a
non-resilient hard stop (re-adjust limit). Operator
Hard Stop Limit (Arm 2)
39
may be at end of travel (re-adjust mounting).
Battery overvoltage
Too much voltage on the battery. Check harness.
40
Make sure there is NOT a 24V battery on a 12V
system.
Battery overcurrent
Possible short of the battery charge harness.
41
Check harness. Make sure you do NOT have a
12V battery on a 24V system.
No battery at boot up
Check battery connections and installation.
Replace batteries if depleted to less than 20V on
42
a 24V system or less than 10V on a 12V system.
Make sure there is NOT a single 12V battery on a
24V system.
43
Failure or missing EXIT loop
Failure or missing loop (SHORT or OPEN -
LiftMaster Plug-in Loop Detector only) Check
44
Failure or missing SHADOW loop
loop wiring throughout connection. May be a
Failure or missing INTERRUPT loop
short in the loop, or an open connection in the
45
loop.
46
Wireless edge battery low
Replace batteries in wireless edge.
51
Pass-point not detected (Arm 1)
Check yellow pass-point wiring. If limits are not
accurate, reprogram.
52
Pass-point not detected (Arm 2)
Brownout occurred
AC/DC board supply dipped below allowable
level. Review power supply and wiring. If
53
rebooting, ensure enough time for discharge of
power to force a fresh boot.
Wireless Second Operator Communication Error Check the second operator for power. If OFF,
restore power and try to run the system. If
54
powered, deactivate the wireless feature and then
reprogram the second operator.
Minimum number of monitored entrapment
Review monitored entrapment protection device
protection devices not installed.
connections. This swing gate operator will
60
operate only after installation of a minimum of
one external safety device in either the open or
close direction.
CLOSE EYE/INTERRUPT held more than 3
Check wired input on main board; check for
61
minutes
alignment or obstruction.
62
CLOSE EDGE held more than 3 minutes
63
OPEN EYE/EDGE held more than 3 minutes
CLOSE EYE/INTERRUPT held more than 3
Check wired input on expansion board; check for
64
minutes
alignment or obstruction.
65
CLOSE EYE/EDGE held more than 3 minutes
66
OPEN EYE/EDGE held more than 3 minutes
Wireless edge triggered more than 3 minutes
Check wired input for wiring issue or
67
obstruction.
68
Wireless edge loss of monitoring
Check wireless edge inputs.
Wireless edge triggered
IF an obstruction occurred, no action required. If
69
an obstruction did NOT occur, check inputs and
wiring.
CLOSE EYE/INTERRUPT triggered, causing
IF an obstruction occurred, no action required. If
70
reversal, preventing close, or resetting TTC
an obstruction did NOT occur, check alignment,
inputs, and wiring on main board.
CLOSE EDGE triggered, causing reversal,
71
preventing close, or canceling TTC
OPEN EYE/EDGE triggered, causing reversal or
72
preventing opening
CLOSE EYE/INTERRUPT triggered, causing
IF an obstruction occurred, no action required. If
73
reversal, preventing close, or resetting TTC
an obstruction did NOT occur, check alignment,
inputs, and wiring on expansion board.
CLOSE EYE/EDGE triggered, causing reversal
74
and preventing close or canceling TTC
OPEN EYE/EDGE triggered, causing reversal or
75
preventing opening
Close input (EYE/EDGE) communication fault
Check inputs and communication method
80
from other operator
between operators, either wired bus or radio.
Ensure operator is powered. May have to erase
Open input (EYE/EDGE) communication fault
the wireless communication and reprogram the
81
from other operator
two operators.
Close input (EYE/EDGE) communication fault
Check the connections between the main board
82
(expansion board)
and the expansion board.
Open input (EYE/EDGE) communication fault
83
(expansion board)
Non-monitored device detected on the wireless
Non-monitored contact closure devices are not
safety system
supported. Make sure connected devices are
84
monitored. Check edges for proper orientation
and resistive end cap connection.
91
Force Reversal (Operator 1)
Check for obstruction. If no obstruction, check
that the mechanical assembly is engaged and
Force Reversal (Operator 2)
free to move. See section on Limit and Force
92
Adjustment, and Obstruction Test in the manual.
93
RPM / STALL Reversal (Operator 1)
Check for obstruction. If no obstruction, check
the operator wiring and that the mechanical
RPM / STALL Reversal (Operator 2)
assembly is engaged and free to move. Replace
94
APE assembly.
99
Normal Operation
No action required
COAXIAL CABLE
ANTENNA
Control Board
DIAGNOSTICS
DIAGNOSTICS
DIAGNOSTICS
DIAGNOSTICS
DIAGNOSTICS
DIAGNOSTICS
(see below)
(see below)
PLUG-IN LOOP DETECTOR
Model LOOPDETLM
Expansion Board
(Optional Accessory)
POWER
POWER
EYE
EYE
1
1
ONLY
ONLY
EYE/
2
EYE/
2
EDGE
EDGE
EYE/
3
EYE/
3
EDGE
EDGE
COM
COM
SBC
SBC
OPN
OPN
CLS
CLS
STP
STP
COM
COM
SHADOW INTERUPT
EXIT
SHADOW INTERUPT
EXIT
SHADOW INTERUPT
EXIT
LOOPS
AUXILIARY RELAYS
Interrupt Loop
SHADOW INTERUPT
EXIT
Shadow Loop
Exit Loop
(Back of the Output Housing)
Outlet
Outlet
Earth Ground Rod
Input Power Connection
24 Vdc
switched
24 Vdc
always on
POWER
POWER
EYE
1
Wireless Edge Kit
ONLY
EYE/
POWER
Model LMWEKITU
2
EDGE
EYE/
3
EYE
EDGE
1
ONLY
COM
EYE/
2
EDGE
EYE/
3
EDGE
COM
SBC
EYE
1
ONLY
OPN
SBC
EYE/
2
EDGE
OPN
CLS
EYE/
3
CLS
EDGE
STP
STP
COM
N.C.
COM
COM
SBC
Control Stations
Jumper
OPN
POWER
CLS
STP
COM
SWITCH SETTINGS
EYE
1
ONLY
EYE/
2
EDGE
RELAY 1
RELAY 2
1
2
3
EYE/
3
EDGE
OFF
OFF
OFF
Relay always off
Relay always off
COM
Energizes at open
OFF
OFF
Energizes at open limit
ON
limit
SBC
Energizes when not
Energizes when not at
OFF
ON
OFF
OPN
at close limit
close limit
CLS
Energizes when
Energizes when motor
OFF
ON
ON
motor is on
is on
STP
Energizes 3 seconds
COM
Energizes 3 seconds prior
prior and during gate
ON
OFF
OFF
and during gate motion
motion
DIAGNOSTICS
Energizes with AC or
Energizes with battery
ON
ON
OFF
solar power
power
Energizes when gate
Energizes when gate is
ON
OFF
ON
is tampered with
tampered with
ON
ON
ON
LEDs will blink
Not used
cycle count
CONTROL BOARD
J15 Plug
Diode
Red
Battery
20W minimum - 60W maximum, wired in parallel
12V 7AH
Battery
12V 7AH
Black
10W 12V
Optional 33AH Battery Configuration
For 33AH battery configuration please use Universal Solar Harness
Kit K94-37236.
Black
The Large Solar Control Box (XLSOLARCONTUL) can be used with
either 7AH or 33AH batteries.
Red
WIRING DIAGRAM
Control Station
Fire Department
Access Control
Device
Exit Loop
Shadow Loop
Interrupt Loop
Photoelectric Sensors
for close cycle
Photoelectric Sensors
Edge Sensor
for open cycle
for open cycle
Edge Sensor
for close cycle
OR
Maglock
Solenoid Lock
(Optional)
(Optional)
(not provided)
OR
Photoelectric Sensors
Photoelectric Sensor
for open or close cycle
for open or close cycle
OR
Photoelectric Sensor
for open or close cycle
OR
RED/GREEN
LIGHT FUNCTIONALITY
Red light
wired to AUX RELAY 1.
Green light
AUX RELAY 1 SWITCHES
GATE STATE
1
1
OFF
2
OFF
3
OFF
CLOSED
Red light OFF*
DIAGNOSTICS
OPENING
Red light ON/FLASH
Red light OFF
OPEN
CLOSING
Red light ON/FLASH
Defined Mid Stop
n/a
Undefined Mid Stop
Red light ON
Timer more than
Red light OFF
5 seconds
Timer less than
Red light ON/FLASH
5 seconds
* For red light ON when gate is closed, set switch 1 on AUX RELAY 1 to ON
CONTROL BOARD
PRIMARY
SECONDARY
PRODUCT
OPERATOR
OPERATOR
ID
Universal Solar Harness Kit (K94-37236)
For 7AH or 33AH batteries
Solar Panels (Optional)
PLUG-IN
TRANSFORMER
10W 12V
Black
Red
Red
Black
Model LA400UL
(not provided)
Edge Sensor
for open or close
cycle
Edge Sensor
for open or close
cycle
wired to AUX RELAY 2.
AUX RELAY 2 SWITCHES
ON
2
ON
3
ON
Green light OFF
Green light OFF
Green light ON
Green light OFF
n/a
Green light OFF
Green light ON
Green light OFF
Attach to outlet metal
chassis with a single screw
ALARM
Red
Black
RESET BUTTON
LiftMaster.com
© 2018, LiftMaster
All Rights Reserved
01-39240-10

Advertisement

loading

Summary of Contents for Chamberlain LA400UL

  • Page 1 WIRING DIAGRAM Model LA400UL Control Station To reduce the risk of INJURY or DEATH: • DISCONNECT power and battery BEFORE installing or servicing operator. Fire Department • Replace ONLY with fuse of same type and rating. • To be compliant with UL325 and industry safety guidelines, qualified monitored...