Create the Interface and Define the Encapsulation
1. Enter interface fr 1 to create a Frame Relay virtual interface labeled 1.
2. Enter frame-relay lmi-type none (contact your service provider for your correct LMI-type) to
configure signaling on the Frame Relay virtual interface 1. The default LMI type is
ANSI (Annex D).
3. Enter no shutdown to activate the interface to pass data.
4. Enter exit to return to the Global Configuration mode.
Create the PVC and Assign an IP Address
1. Enter interface fr 1.1 to create the first PVC assigned to Frame Relay virtual interface 1. This
activates the configuration parameters for the PVC. Your prompt should now display
Router(config-fr1.1)#.
2. Enter frame-relay interface-dlci 16 to assign DLCI 16 to this PVC. (DLCIs should be
supplied by your network provider.)
3. Enter ip address 192.22.72.1 255.255.255.0 to assign an IP address of 192.22.72.1 for this
PVC using a 24-bit subnet mask.
4. Enter exit to return to the Global Configuration mode.
Configure the PPP Interface
The following steps outline configuring a PPP interface (labeled 1) to the NetVanta.
The following steps assume the Global Configuration mode is currently active. Verify the
prompt of the unit displays (config)#.
1. Enter interface ppp 1 to create a PPP interface labeled 1.
2. Enter ip address 192.22.72.1 255.255.255.0 to assign an IP address to the PPP interface
using a 24-bit mask.
3. Enter no shutdown to activate the interface to pass data.
4. Enter exit to return to the Global Configuration mode.
4