Basic alarm parameters

10
Basic alarm parameters
70
Siemens Building Technologies
Fire Safety & Security Products
This dialogue screen allows basic alarm processing parameters to be set in the
system. These include, for example:
Number and connection of alarm lines
The following data is important as otherwise alarms will either not be recognised or not correctly
recognised.
Alarm zone alarm enabling at preset times.
Firstly, you must indicate to which alarm line input on the SIMATRIX you have
connected your first alarm line, and secondly how many alarm lines are used.
These alarm lines will then be correctly allocated if you have connected them in
sequence from first to last to the alarm line inputs on the SIMATRIX, starting with
the first input for alarm lines (setting for 1st alarm line at.. ). The Alarm
line/camera groups dialogue screen allows the setting of further parameters for
each individual alarm line.
Operating
Alarm inputs on the
profile
basic unit
Operating
1 – 32
profile 1
Operating
1 – 32
profile 2
Operating
none
profile 3
Fig. 52
Basic alarm parameters for SIMATRIX NEO
Alarm inputs on the
Alarm inputs on
extension unit
alarm box 1
33 – 64
65 – 192
none
33 – 160
none
1 – 128
Alarm inputs
on alarm box 2
193 – 240
161 – 240
129 – 240