1800129089 DG8960 F0_110 x 154 28/01/13 10:21 Page77
Operation:
• An orange "Calc-Away System" light
located -
fig. 18
starts flashing to tell you that the scale
collector needs rinsing.
• Once the steam generator has cooled,
unscrew the scale collector cover -
IMPORTANT! This operation must
not be carried out unless the steam
generator has been unplugged for at
least two hours and has cooled down
f
completely.
To carry out this operation, the steam
generator must be close to a sink as
water may come out of the tank
when it is opened.
• Unscrew the scale collector and remove
it from the housing; it contains the scale
that has built up in the tank -
• To clean the collector properly, just
rinse it under running water to remove
the scale it contains-
• Put the scale collector back into its
housing and screw it in completely to
keep it watertight -
• Screw the scale collector cover back in
place -
fig.
f

IS THERE A PROBLEM?

Problems
The steam generator does
not switch on or the iron in-
dicator and ON/OFF indica-
tor do not switch on.
Water runs through the
holes in the soleplate.
on the control panel
fig.
fig.
21.
fig.
22.
23.
Possible causes Solutions
The appliance is not switched
on.
You are using the steam
control button before the iron
is hot enough.
Water has condensed in the
pipes because you are using
steam for the first time or you
have not used it for some
time.
You are using the Boost func-
tion before your iron is hot
enough.
The next time you use your iron, press
the "Restart" button on the control pa-
nel to turn off the orange "Calc Away
System collector" indicator.
fig.
19.
Apart from this regular maintenance
process, we recommend that you rinse
the boiler completely every 6 months, or
every 25 times you use your iron.
• Make sure that the steam generator has
been unplugged and allowed to cool for
at least 2 hours.
• Place the steam generator on the edge
of your sink and the iron to one side, on
its base.
• Remove
the
unscrew the scale collector. -
• Hold your steam generator at an angle
and use a jug to fill the boiler with 1/4
litre of untreated tap water. -
• Shake the base unit for a few seconds
20.
then empty it completely into the sink. -
fig.
25-26.
• Fit the scale collector back in its housing
and screw it in tightly to ensure it is
watertight. Do not overtighten the scale
collector -
fig.
• Put the scale collector cover back in
place. -
fig.
The steam generator does not work
without the scale collector.
Regular descaling of your steam
generator helps to maintain its
steam performance over time
Check that your appliance is correctly plugged
in and press the illuminated on/off switch.
Decrease the steam output while ironing at low
temperature (steam output control dial on the
control panel).
Wait for the thermostat light to go out before
activating the steam control button.
Press the steam control on the iron away from
the ironing board until steam comes out of the
iron.
Before you use the Boost function, set your tem-
perature control button to Maximum.
77
collector
cover
fig.
fig.
22.
23.
EN
and
19-20.