3.3 Battery Replacement

The battery is replaced with new one by following of the steps below.
1. Disconnect JP1 on NP board. See Fig. 3.3.
2. Use a desoldering tool to remove the battery from NP board.
3. Solder the replacement battery onto the board.
4. Fix the battery onto the board with silicone sealant.
5. Solder JP1.
(1) Replace the battery only with CR2450 - F2 ST2L (000-144-941).
(2) Never short + and - sides of the cell.
(3) The lithium cell may explode resulting in a fire or chemical burn if mistreated. Do not
recharge, disassemble, or incinerate.
(4) Follow local ordinances or regulations for the disposal.