Bacharach's N
Oxide gas monitor that continuously measures and rapidly detects occupational
exposure to N
Weighing only 8 ounces, the N
performs risk assessments, area monitoring, personal monitoring and leak
detection in environments where there is a risk of exposure to anesthetic
agents. Its measurement resolution is 5 ppm and features both PPM and TWA
measurement capabilities, which can be accessed with just a touch of a
button. Two modes of TWA are available – real time TWA (over 8 hours) and
elapsed time TWA (time unit is switched on). The built-in "auto-stabilization"
feature corrects for any drift when sampling long term. A built-in data-logger
provides traceable readings for record keeping purposes. The N
3010 also includes an internal sampling pump. And, it is not necessary to
span or calibrate the monitor – zeroing in fresh ambient air or with nitrogen
is all that is necessary.
A P P L I C AT I O N S
The N
O Monitor 3010 is a cost-effective monitoring
2
solution for anesthetists, doctors, nurses and
technicians who work in environments where there is
an occupational risk of exposure to Nitrous Oxide,
including hospital operating and recovery rooms,
medical clinics, surgical centers, and dental and
veterinary offices.
ORDERING INFORMATION
PART NO.
19-7109
19-3301
19-3311
19-8027
23-4003
24-1295
19-3337
28
BACHARACH
N
O Monitor 3010
2

Nitrous Oxide Monitor

O Monitor 3010 is an affordable and lightweight personal Nitrous
2
O.
2
O Monitor 3010 is a versatile instrument that
2
DESCRIPTION
N
O Monitor 3010
2
IrDA Interface/Software
Plastic Carrying Case (Small)
Calibration Kit (with regulator & tubing)
Calibration Gas (100% N
17L)
2
Calibration Gas (80 ppm N
2
Small Carrying Case
®
| 1.800.736.4666 | www.bacharach-inc.com
O Monitor
2
F E AT U R E S
• Rapid detection of changing N
• Continuous data-logging – stores up to 800 readings
• 2 TWA capabilities – real time / elapsed time
• Readings can be toggled between TWA and PPM
• No span calibration required – only zero calibration
• Internal pump for remote sampling with low flow indicator
• Built-in, user-activated alarm
• Compact and lightweight
• Easy-to-read LCD display
• 12 hours of operation on a full charge (10 hours with pump)
• Maintenance free, dual wavelength infrared N
• Two-way IrDA communication link
• Pressure compensated sensor
O, 17L)