Fyrite ® - Gas Analyzers - Bacharach 2800 Product Catalog

Hcac & refrigeration
Hide thumbs Also See for 2800:
Table of Contents

Advertisement

Fast, accurate and easy to use instruments for measuring and analyzing carbon dioxide
or oxygen. Fyrite
is produced in three scale ranges.
All six instruments are similar in appearance and size, but differ in important
construction details, as well as in the absorbing fluids.
Each model, therefore, is suitable only for the particular gas
analysis or scale range for which it has been manufactured.
Accuracy is within ±0.5% CO
A P P L I C AT I O N S
0-7.6% CO
2
CO 2 tests of controlled
atmospheres in fruit, vegetable,
meat storage rooms and incubator
monitoring.
0-7.6% O
2
Oxygen determination in flammable
gases; oxygen tests to check
inertness of atmosphere in silos,
fuel tanks, etc.
0-20% CO
2
Flue gas combustion tests; CO
tests of heat treating atmospheres.
0-21% O
2
Flue gas combustion tests, oxygen
deficiency test. Checking oxygen
concentrations in hydrogen cooled
generators and oil sealed inert gas
transformers.
F E AT U R E S
Fyrite
®
Indicators have a broad range; they may be
exposed to ambient temperatures from -30° to 150°F, and
gases up to 850°F may be tested with standard aspirator
sampling equipment (special sampling equipment for
higher gas temperatures or dry gases is available). See
Fyrite
®
Instruction manual 11-9026. For temperatures
above 1400°F, a ceramic sampling tube (Bacharach
No. 11-0164) is available.
16
BACHARACH | 1.800.736.4666 | www.bacharach-inc.com
Gas Analyzers
®
Analyzers are available for either CO
or 0
.
2
2
0-60% CO
Checking CO
in tankers and barges carrying
gasoline and other combustibles;
CO
CO
0-60% O
Oxygen test in connection with
oxygen and gas anesthesiology.
2
®
Fyrite
or O
analysis, and each model
2
2
2
in inert gas blankets
2
tests on lime kilns; checking
2
in sewage plant digesters.
2
2
O P E R AT I O N
Fyrite
®
absorbing fluid is selective in the chemical absorption
of carbon dioxide or oxygen, respectively. Therefore, the
Fyrite
®
's accuracy, which is well within the range required
for industrial and professional applications, does not
depend upon complicated sequential test procedures.
In addition, Fyrite
of most background gases in the sample.
The number of tests possible with one fluid charge
depends on the concentration of samples being tested. At
midpoint scale reading the CO
approximately 300 gas samples and the O
tests. The need to replace fluid can be easily determined
with a simple test, and replacement is an easy procedure.
These test procedures, as well as other good information,
®
Part
are provided in the Fyrite
®
readings are unaffected by the presence
fluid is good for
2
fluid for 100
2
®
manual 11-9026