3.7 General Wiring Diagram

AC Input Voltage
L1(R) L2(S)
Digital Input
Section
External
Analog
Inputs
Shielded wire
Main circuit
Notes:
*1: Use L1 (L) and L3 (N) for single phase input
*2: Use jumper JP1 to select between Sink (NPN, with 24VG common) or Source (PNP, with +24V
common) for multi-function digital input terminals S1~S6.
*3: Use jumper JP2 to switch between voltage and current input for Multi-function analog input 1 (AI1).
*4: Use jumper JP3 to switch between voltage and current input for Multi-function analog input 1 (AI2).
*5: Run Permissive input SF and SG is a normally open input. This input should be open to enable the
inverter output. To activate this input place a jumper wire between SF and SG.
Downloaded from Dealers Industrial Equipment -- Visit
L3(T)
FWD / STOP
REV / STOP
Preset Speed 1
Multi-
Preset Speed 2
Functional
Digital Inputs
Preset Speed 3
Reset
Factory Default
Output Disable
0 ~ 10V
0 ~ 20mA
0V
P
Twisted-pair shielded wire
Control circuit
P
*1
L1(L)
+
L2
-
L3(N)
E
S1
S2
S3
S4
S5
S6
COM (NPN)
+24V (PNP)
E (Ground)
SF
*5
SG
+10V: Power for Analog Input
(max. 20mA)
AI1: Multi-Function Analog Input
P
AI2: Multi-Function Analog Input
P
AGND: Analog Signal Common
NPN
*2
JP1
PNP
E (Ground)
3-11
https://DealersElectric.com
Braking Resistor
BR
3Ø Induction motor
T1
T2
T3
Ground
< 100Ω
E
RS485
CON 2
1:Data+
2:Data-
3:Data+
4:RXD0
5:TXD0
6:Data-
7:5V
Pin 1 to Pin 8
8:GND
Relay Output
(R1A)
Multi-Function
NO
Relay Output
(R1C)
E510
NC
(R1B)
Contact rating:
250 VAC < 1.0A
30 VDC < 1.0A
R2A
NO
R2B
Relay Output
AO
Analog
Output
Analog Outputs
0 – 10 VDC
AGND
AI1
AI2
*3
*4
JP2
JP3
AV1
AV2
E (Ground)