Plain Tile And Slate Roof Cover; Uncovering The Roof; Fitting The Timbers - Viessmann Vitosol-F Installation Instructions Manual

Type svka, svkg flat-plate collector for pitched roofs, roof integration for 1 collector
Table of Contents

Advertisement

Components
(cont.)

Plain tile and slate roof cover

120 x 40
8 x 120
1
2
6 x 30
5
6
7
4
Fig. 2
Timber
1
120 x 30 x 1600 mm
Screws 8 x 120 mm
2
Timber
3
48 x 30 x 1600 mm
Front panel with lead flashing
4
Mounting plate with butyl strip
5
Zinc-plated chipboard screw (Spax-s) 6 x 30 mm
6
Fixing clamp with butyl strip
7
Retaining bracket
8

Uncovering the roof

Required roof area: 2900 x 1800 mm
To prevent any damage to the ridge cover, allow suf-
ficient clearance on the ridge side; at least 3 rows for
tiled roof cover.
Note
With tiled roof cover, also maintain a width of at
least 3 tiles at the roof verges.
If necessary, install a snow guard.

Fitting the timbers

Components
Timber
1
6 x 30
6
8
qR
qT
qQ
qP
9
60 x 40
3
qE
qZ
qU
qW
Lower casing
9
Right casing
qP
Left casing
qQ
Upper casing
qW
Nail
qE
Nocky panel, right
qR
Nocky panel, right, trimmed
qT
Nocky panel, left
qZ
Nocky panel, left, trimmed
qU
Provide a roof hatch near the collectors for inspec-
tion and maintenance.
Take additional measures on site to protect against
water penetration as a result of snow and wind pres-
sure, e.g. sarking membranes (accessories).
120 x 30 x 1600 mm
Screws 8 x 120 mm
2
Timber
3
48 x 30 x 1600 mm
7