[8] Adjustment Items

Adjustment items
1. AF LED Angle Adjustment
2. Lens Adjustment
3. AWB Adjustment
4. CCD White Point Defect Detect Adjustment
5. CCD Black Point Defect Detect Adjustment
in Lighted
6-1. PAF Uniform Adjustment
6-2. PAF Parallax Adjustment
6-3. PAF Distance Adjustment
7-1. LCD H AFC Adjustment
7-2. LCD RGB Offset Adjustment
7-3. LCD Gain Adjustment
7-4. LCD Red Brightness Adjustment
7-5. LCD Blue Brightness Adjustment
7-6. LCD VcomPP Adjustment

[9] Notice after adjustment

Make sure to reset the camera after adjustment.
Method to reset the camera;
1. Set the camera to the shooting mode and turn power on.
2. Open the card cover (a warning "CARD-COVER OPEN" appears).
3. Press OK button and LCD button simultaneously for about three seconds.
(CAMERA/SDK setup wizard appears.)
4. Choose "RESET" from "CAMERA" and press OK button.
5. Turn the power of the camera off.
C. ADJUSTMENT METHOD
CA1(CCD)
C-12
C-7070 Wide Zoom
Changed repair parts
LENS FINDER FPC
CP1