Cooling Unit Control (Cuc); Useful Suggestions; Defrosting, Cleaning And Maintenance; Automatic Defrost Function - Dometic RH 465LD Operating Instructions Manual

Table of Contents

Advertisement

GB

5.3. Cooling unit control (CUC)

The electronic checks the function after every
defrosting period (every 24 hours) by measuring the
evaporator temperature drop. If it registers a problem
the refrigerator will shut down and the LEDs of the
interior light will begin to flash continously. If this
happens you should check whether the refrigerator
has been overloaded, that the door was properly
closed, that the cooling unit ventilation is correct and
that the refrigerator is levelled. After checking, unplug
the refrigerator at least for 10 seconds and plug in
again. This resets the unit and it will function again. If
no sign of cooling there is a problem and you should
then contact Dometic service.
6. Useful suggestion
Do not overfill the appliance. If possible, always store
pre-cooled food and/or drinks. It is advisable to leave
some space between the products in the cabinet to
ensure efficient and even cooling. If the shelves are
packed too tightly there may be unacceptable
temperature variations.
7. Defrosting, cleaning and
maintenance
Frost will gradually form on the cooling plate and it
must not be allowed to become too thick since it
restricts the cooling.
This miniBar is fitted with a fully automatic electronic
temperature regulator.
The frost will melt and the defrost water will run
through the drain tube from the drip channel into an
evaporating vessel located at the bottom rear of the
refrigerator. (Fig. 5) The defrost water will evaporate
automatically into the circulating air and the vessel will
not need emptying.
Figure 3.
To switch off the unit, disconnect the refrigerator from
the electricity supply and leave the cabinet door open.
After defrosting the cabinet interior should be wiped
out with a clean, damp cloth.
6

7.1. Automatic defrost function

The first defrosting phase commences 39 hours
after the start and lasts for two hours.
After this, the device operates for 22 hours at a
time, followed by a defrosting period of 2 hours.

7.2. Interior light

(fig. 4.)
Two light-emitting diodes (A) on an electronic PCB
illuminate the cooling compartment when the door
is opened.
Two sensors (B) control whether the door is open
or not and the LEDs and the door control as well
will work accordingly.
B
Figure 4.
7.3. Automatic Door Control LED
(ADC) optional
The LED (Fig. 5.A) indicated whether the miniBar
door has been opened. If so then:
1. Open the miniBar, check the content in the
compartement and if necessary, replenish.
2. Reset the door control signal by helding the
Remote control against the door opening sensor
(Fig. 4. B) and push the button .
3. Close the miniBar.
Figure 5.
A

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mb20-60

Table of Contents