2.5

USER CONTROLS AND STATUS LED's

The following is a description of the user control function and status LED's found on the WOC-2 motor
control enclosure:
DRIVE ON – Indicates when power has been enabled to the oscillation slide
motor and to the mechanical brake assembly on the slide.
CCW LIMIT – This LED indicates the status of the CCW (Left) position limit
switch in the mechanical slide assembly. LED off indicates limit is not active. LED
on indicates the CCW limit has been set. (Note: When this limit is active all CCW
slide motion is disabled. If the oscillation is active when the limit is tripped the
oscillation will be disabled.)
CW LIMIT – This LED indicates the status of the CW (Right) position limit switch
in the mechanical slide assembly. LED off indicates limit is not active. LED on
indicates the CW limit has been set. (Note: When this limit is active all CW slide
motion is disabled. If the oscillation is active when the limit is tripped the
oscillation will be disabled.)
COMM – This LED indicates the status of the isolated RS-485 serial
communications. A green LED indicates no communications and a RED led
indication active serial communication.
NET PWR – This LED indicates that the isolated RS-485 communications port
has power applied.
+5V – This LED indicates that the five volt power supply is functioning.
+36V – This LED Indicates that the motor power supply is functioning
POWER – This switch is used to activate the WOC-2 controller.