2-28. OPTICAL PICK-UP (CMS-S76RFS7G) (OP1)

qa optical pick-up
(CMS-S76RFS7G)
(OP1)
5 insulator
screw
0 insulator
5 insulator screw
6 Remove the optical pick-up block
in the direction of the arrow.
4 three
claws
1 two
claws
3 Draw out the tray.
Note 3: When you can not draw out the tray,
please refer to "HOW TO OPEN THE TRAY
WHEN POWER SWITCH TURN OFF" on page 6.
Note 1: When installing the flexible flat cable, ensure that
the colored line is not slanted after insertion.
OK
Insert is straight to the interior.
flexible flat
cable
colored line
connector
32
2 chuck holder block
5 insulator
0 insulator
0 insulator
1 claw
1 claw
NG
Insert is incline
flexible flat
cable
colored line
connector
e i e
screw
5 insulator screw
7 connector
0 insulator
Wire e i
9 connector
1 claw
8 flexible flat cable (24 core)
(FFC1)
1 claw
Note 2: When you install the connector, please install them correctly.
There is a possibility that this machine damages when not
correctly installing it.
OK
Insert is straight
to the interior.
connector
connector
e
re
e i
terminal face is below side.
ie
B
ie
NG
Insert is shallow
Insert is incline
connector
connector
connector
NG
connector