Signal Generator; Power Pack; Noise Emission; Dimensions And Weights - Bosch FSA 720 Instruction Manual

Vehicle system analysis
Hide thumbs Also See for FSA 720:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 15
7.

Signal generator

Function
Specification
Amplitude
-10 V – 12 V
(Load < 10 mA) to ground
Signal shapes
DC, sinus, triangle, square
Frequency range
1 Hz – 1 kHz
Output current
max. 75 mA
Impedance
approx. 60 Ohm
Symmetry
10 % – 90 %
(triangle, square)
Curve generation
Output rate up to 100000 values/s,
Resolution 8 bit,
Y-full range adjustable ( bit),
Unipolar / bipolar mode
Short-circuit resistance
< 50 V static
to interference voltage
Short-circuit resistance
< 500 V / 1 ms dynamic
to interference voltage
Automatically switched filter and damping elements
for improvement of signal quality.
Automatic cutoff for short circuit, interference volt-
age detection at start of signal generator.
Bosch Diagnostics
Technical data | FSA 70 | 7
7.3

Power pack

Function
Input voltage
Input frequency
Output voltage
Operating temperature
7.4

Noise emission

< 70 dB(A)
7.5

Dimensions and weights

Function
Dimensions H x W x D:
Weight
en
Specification
90 VAC – 264 VAC
47 Hz – 63 Hz
15 V
0 °C – 40 °C
Specification
180 x 550 x 200 mm
8 kg
|
1 689 979 894
2007-01-30

Advertisement

Table of Contents
loading

Table of Contents