11.3 Start-Up Wizard

The setup wizard should run the first time the unit is
powered on. The wizard must be completed before
the boiler can be used.
1. Set the Language
English
French
2. Set the time.
YYYY:MM:DD:HH:MM:SS
3.
Set the units to display.
Celsius (°C), L/M, Meter
Fahrenheit (°F), GPM, Feet
4. Check the gas type.
Natural Gas
Propane Gas
5. Installation Elevation Check
See manual for adjustments needed above
2,000 ft.
6. Set the zone system
Zone Pump System
Zone Valve System
7. Set the outdoor reset ON/OFF
Enable
Disable
7-1. Set the outdoor reset curve(Enable select)
Finned Tube Baseboard
FAN Coil
Cast Iron Baseboard
Low mass Radiant
High mass Radiant
Radiator
Custom
7-2. Set the outdoor high temp
7-3. Set the outdoor low temp
7-4. Set the WWSD temp
8. Set the auto-fill pressure
9. Set the DHW recirculation
No Recirculation
Combi Pre-heat
External Recirculation
10. Set the Combi-Pre heat mode(Combi Pre-heat
select)
Always On/Intelligent/Weekly
11. Set the External Recirculation mode(External
Recirculation select)
Always On/Intelligent/Weekly/Aquastat/
Hotbutton
12. Setup Summary
Once the Setup Wizard is finished, a summary
of the settings will be displayed. Press the OK
button (OK) at each summary screen until the
air purge mode displayed. Settings made in the
Setup Wizard can be adjusted from the Main
Menu and Installer Menu as described in Section
11.5 and 11.6.

11.4 Adjusting the Temperature

11.4.1 Adjusting the Space Heating
Temperature
To adjust the heating temperature:
1. In normal operation mode, rotate the Command
dial (
) until the space heating temperature
(
) is highlighted on the screen.
Operating the Boiler
103