Step 1 - Basic Operation Checkout Procedures - Trane Thermo King TriPac Envidia Installation Manual

Auxiliary power unit edition
Hide thumbs Also See for Thermo King TriPac Envidia:
Table of Contents

Advertisement

Operation Checkout Procedures
An operation checkout procedure must be performed after the TriPac Envidia installation has been completed. This
procedure will confirm the operation of the heating and air conditioning systems, and will verify the TriPac Envidia
batteries are charging and discharging properly. Any alarm codes that may have been set can also be checked and
cleared. This checkout procedure will be done in two steps:
S S T T E E P P 1 1 — — Use the TriPac Envidia HMI controller to verify basic system operation.
S S T T E E P P 2 2 — — Use a laptop PC connected directly to the TriPac Envidia Base Controller module using the Envidia Service
Tool and Service Test Mode to verify system operation in more detail.
The Envidia Service Tool communication software is in the service computer and will transfer information directly to a
laptop PC. This software provides the technician with system interface, flash load system upgrades, real time system
information retrieval, Service Test Mode and Alarm clearing capabilities. The following tools will be required:
Laptop Computer (IBM Compatible)
USB Adapter Harness (204-2000 or USB Mini-B)
Envidia Service Tool Software (See Envidia Service Tool Location Procedures below)
Thermo King Technician or Installer
Go to:
www.thermoking.com
a.
iService Login, provide user name and password
b.
Resources/Info Central/Software & Downloads/APU
c.
Click on "Envidia Service Tool"
d.
Select Save in the dialog box
e.
File will be saved to your default Downloads folder
f.
Locate the Envidia Service Tool.exe file. Move it to an easy to locate folder.
Non-Thermo King Operator or Installer
Go to:
www.thermoking.com
a.
North America/Products/Auxiliary Power Units
b.
Scroll to bottom of page. Select the TriPac Envidia "LEARN MORE" box.
c.
Select "DOWNLOADS" tab
d.
Select Envidia Service Tool "DOWNLOAD" box. Select Save in the dialog box
e.
File will be saved to your default Downloads folder
f.
Locate the Envidia Service Tool.exe file. Move it to an easy to locate folder
Step 1 – Basic Operation Checkout Procedures
The following basic operation checkout procedures will be performed using the TriPac Envidia HMI controller.
N N o o t t e e : : Make sure the truck's engine is off and ignition switch is in the off position.
1. Rotate Mode Selection knob to F F a a n n M M o o d d e e .
2. Rotate Temperature Selection knob so white dot is at the top.
3. Press Mode Selection knob for at least one second to turn the TriPac Envidia system ON.
a. Fan icon should flash for several seconds then stay on.
b. Evaporator fan may not start.
c. Battery level bars should illuminate based on state of battery charge. It may take up to 30 seconds for the battery
level bars to illuminate.
4. Rotate Fan Speed Selection knob clockwise.
N N o o t t e e : : There will be a two second delay in response to changes made using the HMI Controller.
a. Fan speed LED indicators should increase.
b. Evaporator fan speed should increase.
5. Rotate Fan Speed Selection knob counterclockwise.