Electrical Wiring and HMI Controller Installation Requirements

I I m m p p o o r r t t a a n n t t : : See "Electrical Standards" in Section 10 of the Thermo King TriPac Installation and Standards Guide (TK
56498). THESE STANDARDS MUST BE FOLLOWED!
Electrical wiring should be installed and routed in such a way as to allow for vibration and movement of the cab.
THEY SHOULD NEVER BE STRETCHED TIGHT!
Always keep electrical wiring from rubbing or chafing against sharp metal objects, rotating components or hot
objects.
All electrical wiring should be neatly routed and secured with band wraps or clamps.
Do note route or bundle 110Vac wires together with 12Vdc wires.
Do not route electrical wires, harness or battery cables together with fuel lines.
Excess length of battery cables should be cut off to reduce voltage drop.
Superlube (203-524) or equivalent should be applied to all electrical connections.
All main power and ground accessory connections must be installed directly on top of the truck's battery terminal
posts and tightened securely. DO NOT INSTALL UNDER OEM BATTERY CABLES!

D2 / D4 Heater Installation Requirements (Units with Heat Option)

I I m m p p o o r r t t a a n n t t : : See "Heater Installation Standards" in Section 7 of the Thermo King TriPac Installation and Standards
Guide (TK 56498). THESE STANDARDS MUST BE FOLLOWED!
Determine the best location of the heater inside the sleeper, typically under the bunk. Allow clearance for
dismantling for service.
Install heater so it will maintain a minimum distance of 2.00 inches (50.8 mm) from any heat sensitive or flammable
material.
The heater must only be mounted on a flat horizontal surface.
Heater must be installed flush with the floor pan (i.e. sheet metal, fiberglass, etc.) to ensure proper sealing of the
mounting plate and gasket.
All edges of access holes made in fiberglass and wood composite floors must be sealed correctly with (installer
supplied) fiberglass cloth and resin.
Outside air intake and exhaust hoses must be installed correctly for the heater to operate safely.
Exhaust hose should be mounted slightly downwards to help drain off condensation.
Install exhaust hose so it will maintain a minimum distance of 2.00 inches (50.8 mm) from any heat sensitive or
flammable material.
Inside air inlet and outlet ducts must be installed correctly for the heater to operate safely.
Pulse type fuel pump outlet must be installed at a 15 to 35 degree angle up from horizontal to operate correctly.
Fuel pickup tube must be installed correctly in the fuel tank or the heater will not operate.
Fuel line from the pickup tube to the fuel pump to the heater should be routed at a continuous rise. Use a hose cutter
or sharp knife to cut plastic fuel lines. Do not use a wire cutter as this will pinch the plastic fuel line closed.
Do not route electrical wires, harness or battery cables together with fuel lines.
BEFORE operating the heater, the fuel lines must be bled of air using the Heater Priming Harness (204-1144) or
damage to the fuel pump will result.
The Diagnostic Code Reader (204-1143) must be used to setup and operate the heater in the run-in mode.
TK 56459-19-IM-EN
T T i i p p s s F F o o r r a a S S u u c c c c e e s s s s f f u u l l I I n n s s t t a a l l l l a a t t i i o o n n
11