Measuring Mode
Ambient Light
Mode
Cordless Flash
Mode
Cord (PC) Flash
Mode
No. Display Mode Name
1 [Text] Icon
2 [Spectrum] Icon
3 [CRI] Icon
4 [TM-30] Icon
5 [SSI] Icon
6 [TLCI/TLMF] Icon
7 [CIE1931 (CIE1964)]
Icon
8 [CIE1976] Icon
9 [Spectrum
Comparison] Icon
 [CRI Comparison]
Icon
 [CIE1931 (CIE1964)
Comparison] Icon
 [CIE1976
Comparison] Icon
 [Setting] Icon
6. Tool Box
Touching the "Tool Box (
screen shifts to the Tool Box screen where frequently used
functions are listed.
7. Setting
Touching the "Setting" icon in the Display Mode
Selection screen shifts the display to the Setting
screen.
Here you can set functions and display methods
required for measurement in advance.
Icon
Measures continuous light such as sunlight, tungsten, fluorescent, and LED
lights.
Detects flash light without meter-flash connection after Measuring
Button pressed to arm meter (for 90 seconds) and flash fired separately.
Detects flash light with PC (synchro) cord meter-flash connection.
Displays user-selected 5 items in numeric values.
Displays 3 user-selected values and spectrum distribution graph.
Displays the selected average CRI (Ra) or individual CRI (R1 ~ R15) numerically.
Each CRI is displayed in a bar graph.
Displays three current measurement values (selectable) and color vector graphic.
Displays the current measurement values (color temperature, ⊿ uv and SSI) and
SSI spectrum graph.
Displays the current measurement values and memorized values (in color
temperature and ⊿ uv), TLCI and TLMF with spectrum graph.
Displays the preset data together with the CIE1931 chromaticity diagram (or
CIE1964 chromaticity diagram for a 10° viewing angle).
Displays the measurement result together with the CIE1976 chromaticity diagram.
Compares the current measurement value and up to 2 memorized values as yellow
and/or red lines in the spectrum distribution graph.
Compares the current measurement value and memoried value to show the color
temperature and average CRI (Ra). Also, individual CRI (R1 to R15) is displayed in a
bar graph.
Displays the preset data and the stored measurement value (up to 2 types of data)
together with the x and y coordinates in the CIE1931 chromaticity diagram (or
CIE1964 chromaticity diagram for a 10° viewing angle).
Displays the measured result and the stored measurement value (up to 2 types of
data) together with the u' and v' coordinates on the CIE1976 chromaticity diagram.
Displays Setting screen. (
Description
Description
7.Setting)
)" icon in any measurement
[Tool Box Screen]
[Setting (Page 1, page2) Screen]