D) Configuration Parameters; E) Technical Data - Traulsen Flexdrawer TF031D3 Owner's Manual

Convertible two drawer refrigerator/freezer
Table of Contents

Advertisement

VI. d - CONFIGURATION PARAMETERS
Parameter Configuration:
• To get access to the parameter configuration menu,
press button
and
• With button
or
modified.
• Press button
to display the value.
• By keeping button
set the desired value.
• When button
is released, the newly programmed
value is stored and the following parameter is displayed.
• To exit from the setup, press button
seconds.
VI. e - TECHNICAL DATA
Power supply
BD1-28....W
100-240Vac ±10%, 50/60Hz, 3W
Relay output max loads (240Vac)
BD1-28..S/T..-.
Compressor
16A resistive
12 FLA 48 RLA
Evap. Fan
16A resistive
4 FLA 12 RLA
Defrost
16A resistive
4 FLA 12 RLA
Auxiliary loads 1
7A resistive
Auxiliary loads 2
7A resistive
Input
NTC 10KΩ@25°C
Measurement Range
<0.5 within the measurement range
Operating Conditions
-10... +50°C; 15%...80% r.H.
CE (Approvals and Reference Norms)
EN60730-1; EN60730-2-9; EN55022 (Class B); EN50082-1
VI. CONTROL BASICS
for 5 seconds.
select the parameter to be
pressed, use button
or wait for 30
BD1-28..Q/R..-.
12A resistive
12 FLA 48 RLA
8A resistive
4 FLA 12 RLA
16A resistive
4 FLA 12 RLA
7A resistive
7A resistive
LAE Part No. SN4...
or
to
-7-