Receipt Inspection; Installation; C) Legs Or Casters; D) Cord & Plug - Traulsen Flexdrawer TF031D3 Owner's Manual

Convertible two drawer refrigerator/freezer
Table of Contents

Advertisement

II. RECEIPT INSPECTION
II. a - RECEIPT INSPECTION
All Traulsen products are factory tested for performance
and are free from defects when shipped. The utmost care
has been taken in crating this product to protect against
damage in transit.
You should carefully inspect your Traulsen unit for damage
upon delivery. If damage is detected, you should save all
the crating materials and make note on the carrier's Bill of
Lading describing the damage. A freight claim should be
filed immediately. If damage is subsequently noted during
or immediately after installation, contact our customer care
team to file a freight claim. There is a fifteen (15) day limit
to file freight damage with the carrier. Under no condition
may a damaged unit be returned to Traulsen without first
obtaining written permission (return authorization). You may
contact Hobart/Traulsen customer care at 800-333-7447 to
request a return or file a claim.
III. INSTALLATION
III. a - LOCATION
Select a proper location for your Traulsen unit, away from
extreme heat and allow proper clearance for air circulation
(see section III.f).
III. b - PACKAGING
The Traulsen unit is shipped from the factory secured to
a sturdy wooden pallet with a steel strap and packaged in
durable wood crating.
Most exterior stainless steel and aluminum surfaces have
a protective vinyl covering to prevent scratching during
manufacturing, shipping and installation. After the unit is
installed in place of service, remove and discard the covering
from all surfaces.
To remove the wooden pallet, first if at all possible, we
suggest that the cabinet remain strapped to the pallet during
all transportation to the point of final installation. The strap
can then be removed with metal shears. Be careful as the
steel strap is under tension and will release once cut.
NOTE: Traulsen does not recommend laying the unit down
on its front or side or back. However, if you must only lay
unit on the front of side, not the back and please be certain
to allow the unit to remain in an upright position afterwards
for 24 hours before plugging it in so that the compressor oils
and refrigerant may settle.
III. INSTALLATION (continued)
III. c - LEGS OR CASTERS
This Traulsen product is shipped from the factory with casters
installed. Level the cabinet using a level or pan of water in
the bottom of the cabinet.
Legs are available as an optional accessory kit. These are
shipped inside the cabinet in a cardboard box.
THE CABINET MUST BE BLOCKED AND
STABLE BEFORE INSTALLING LEGS. UNITS ARE NOT
DESIGNED TO BE MOVED WHILE ON LEGS. IF THE UNIT
REQUIRES MOVING, A PALLET JACK OR FORKLIFT
SHOULD BE USED TO PREVENT DAMAGE.
On units with legs, turn the adjustable feet in or out to level
the cabinet side-to-side and front-to-back. Units with casters
should be placed on level floor.
III. d - CORD & PLUG
All Traulsen models are supplied with a cord & plug attached.
It is shipped coiled and secured by a nylon strip to the back
of the cabinet near condensing unit area. For your safety and
protection, all units supplied with a cord and plug includes
a special three-prong grounding plug on the service cord.
Select only a dedicated electrical outlet with grounding plug
for power source.
NOTE: Do not under any circumstances cut or remove the
round grounding prong from the plug or use an extension
cord.
III. e - POWER SUPPLY
The supply voltage should be checked prior to connection
to be certain that proper voltage for the cabinet wiring
is available (refer to the serial tag to determine correct
unit voltage). Make connections in accordance with local
electrical codes. Use qualified electricians.
Use of a separate, dedicated circuit is required. Size wiring
to handle indicated load and provide necessary over current
protector in circuit (see amperage requirements on the unit's
serial tag).
III. f - CLEARANCE
In order to assure optimum performance, the condensing
unit of your Traulsen unit MUST have an adequate supply of
air for cooling purposes. Therefore, 1" stoppers in the back
are integral part of the unit. Space around these stoppers
should not be blocked to provide proper air exhaust. There
are no clearance requirements for the sides.
NOTE: Do not install the cabinet without casters.
-2-