6
REPLACEMENT OF CC-LINK

6.6.3 Comparison of link special relay (SB)/link special register (SW)

(1) A/AnS series
The following table shows SB/SW which have different application on the A series and the Q series.
(a) Link special relay (SB)
Number
SB0001
SB0003
SB0007
SB000B
SB000C
SB000D
SB0042
SB0043
SB0046
SB004E
SB004F
SB0057
SB0058
SB005A
SB005B
SB005C
SB005D
SB005E
SB005F
Name
AJ61BT11/A1SJ61BT11
Master station switching data
link start
-
Master station switch data link
start acceptance
Master station switch data link
start complete
-
Parameter setting test
acceptance status
Parameter setting test
complete status
-
: Compatible,
QJ61BT11N
Refresh instruction at standby
master switching
Refresh instruction when
changing parameters by the
dedicated instruction
Master station duplication error
canceling request
Transmission speed test
request
Forced master switching
Remote device station
initialization procedure
registration instruction
Refresh instruction
acknowledgement status at
standby master switching
Refresh instruction complete
status at standby master
switching
Forced master switching
executable status
Parameter information read
acknowledgement status
Parameter information read
completion status
Master station duplication error
canceling acknowledgement
Master station duplication error
canceling complete
Master switching request
acknowledgement
Master switching request
complete
Forced master switching
request acknowledgement
Forced master switching
request complete
Execution status of remote
device station initialization
procedure
Completion status of remote
device station initialization
procedure
: Partial change required, × : Incompatible
Compat-
Precautions for replacement
ibility
The specifications of A/AnS
series and Q series are the
same.
Use for setting network
parameters with RLPASET
instruction.
Added on the Q series and
replacement is not applied.
Added on the Q series and
replacement is not applied.
The functions of A/AnS series
are different from those of Q
series.
Since the parameter setting test
×
function is not required for the
Q series, delete the sequence
program for the corresponding
function.
Added on the Q series and
replacement is not applied.
6
- 18