To Prevent Battery Explosion; Light Beam Hazard Distance (Hd) - Barco Athena DP2K-6E User Safety & Environmental Information

Hide thumbs Also See for Athena DP2K-6E:
Table of Contents

Advertisement

W
ARNING
Only trained and qualified technical service personnel are allowed to handle the xenon lamp.
C
AUTION
of the bulb increases the pressure to a level at which the bulb may explode if not handled in strict accordance
to the manufacturer's instructions. The bulb is stable at room temperature, but may still explode if dropped or
otherwise mishandled. Whenever the lamp house, containing a xenon lamp, has to be dismantled or whenever
the protective container or cloth has to be removed from the xenon lamp, authorized protective clothing MUST
be worn!

To prevent battery explosion

Danger of explosion if battery is incorrectly installed.
Replace only with the same or equivalent type recommended by the manufacturer.
For disposal of used batteries, always consult federal, state, local and provincial hazardous waste disposal rules and regulations
to ensure proper disposal.
Safety Data Sheets for Hazardous Chemicals
For safe handling information on chemical products, consult the Safety Data Sheet (SDS). SDSs are available upon request via
safetydatasheets@barco.com.
1.4

Light beam Hazard Distance (HD)

HD
Light beam Hazard Distance (HD) is the distance from the source at which the intensity or the energy per surface unit
becomes lower than the applicable safety limit. The light beam can thus be considered as dangerous if the operator
is closer from the source than the HD.
Restriction Zone (RZ) based on the HD
The HD is defined from the projection lens surface towards the position of the lowest projected beam where the irradiance equals
the applicable safety limit. The HD depends on the amount of lumens produced by the projector and the type of lens installed. See
next chapter HD in function of the lens Throw Ratio (TR).
To protect untrained users the installation shall comply with the following installation requirements: light output levels in excess of the
limits shall not be permitted at any point less than 2.0 meters (SH image 1-1) above any surface upon which persons are assumed
to stand or 1 meter (SW image 1-1) below or in lateral separation from any place where such persons are assumed to be. See
image 1-1.
RA
TH
SH
(A) SIDE VIEW
Image 1-1
A
Side view.
B
Top view.
RA Restricted Access location (booth area of projector).
PR Projector.
TH
Theater.
RZ
Restriction Zone in the theater.
SH Separation Height. Must be minimum 2 meter.
R5906793 ATHENA 26/01/2018
:
The user is not permitted to perform or attempt any phase of xenon lamp handling or service.
:
Xenon compact arc lamps are highly pressurized. When ignited, the normal operating temperature
RZ
SH
1. Safety & Environmental Information
TH
SW
RA
PR
SW
(B) TOP VIEW
SW
RZ
SW
5