Stop/Check Valve Operation; Table 4-2. Stop/Check Valve Open Positions - Emerson VILTER VSS Installation, Operation And Service Manual

Single screw bare shaft compressor
Hide thumbs Also See for VILTER VSS:
Table of Contents

Advertisement

Section 4 • Operation

Stop/Check Valve Operation

Valve Size
Number of Turns Open
(From Closed Position)
1
Doesn´t apply to: VSM-97, VSM-113, VSM-127
VSS/VSR/VSM/VSH/VSSH Compressor • Installation, Operation and Service Manual • Emerson • 35391S
1

Table 4-2. Stop/Check Valve Open Positions

1.5"
2"
2
2.25
2.5"
3"
4"
2.75
3.25
4.5
Auto:
In the "Auto Position", the stop valve is operating as a check
valve, allowing flow in the directions of the arrows.
To set the valve to the automatic position, fully close the
valve, and turn the stem out as indicated by the chart below.
Closed:
In the manually "Closed Position", the stop check is operat-
ing as a conventional stop valve, not allowing flow in either
direction.
Open:
In the manually " Open Position", with the valve stem fully
back seated, the valve disc is lifted slightly, allowing flow in
either direction.
5"
6"
8"
3.75
5.75
7.75
4 – 17

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vilter vsrVilter vshVilter vsmVilter vssh