Communication/Output settings
B.1
Summary table of communications/output
settings
Based on switch position on the 3400 CPU board and Option board if installed, indicate the
appropriate configuration for each communication/output parameters on the 3400
electronics. Use these parameters to configure the 3410 Series electronics.
Table B-1: Communications/output settings summary table
Output Type
Serial Port A
Serial Port B
Serial Port C
Digital Output 1A
Digital Output 1B
Frequency Output 1A
Digital Output 2A
3410 Series Electronics Upgrade kit instructions
Communication/Output settings
(Check electronics switch settings and circle
appropriate box for each output)
Not Used
RS-232 (if
RS-485
(if J6 not
S3 is set to
Half Duplex
used)
RS232)
(if S3 is set
to RS-485
and S5-1 is
set to Half
Not Used
RS-232 (if
RS-485
(if J7 not
S4 is set to
Half Duplex
used)
RS232)
(if S4 is set
to RS482
and S5-2 is
set to Half)
Not Used
RS-232 (if
RS-485
(if J16 not
S10 is set
Half Duplex
used)
to RS232)
(if S10 is
set to
RS-485)
Not Used
TTL (if S8-1
Open
(if J4-2 not
is set to
Collector (if
used)
TTL)
S8-1 is set
to OC)
Not Used
TTL (if S8-2
Open
(if J4-1 not
is set to
Collector (if
used)
TTL)
S8-2 is set
to OC)
Not Used
TTL (if S8-3
Open
(if J4-1 not
is set to
Collector (if
used)
TTL)
S8-3 is set
to OC)
Not Used
TTL (if S9-1
Open
(if J5-2 not
is set to
Collector (if
used)
TTL)
S8-1 is set
to OC)
July 2019
RS-485 Full
Duplex (if
S3 is set to
RS-485 and
S5-1 is set
to Full
RS-485 Full
Duplex (if
S4 is set to
RS-485 and
S5-2 is set
to Full)