Introduction
This Installation Guide provides instructions for
installation, startup and adjustment. To receive a copy of
the Instruction Manual, contact your local Sales Office or
view a copy at www.fisher.com. For further information
refer to: Type HSR Instruction Manual D103074X012.
PED Categories
This product may be used as a safety accessory with
pressure equipment in the following Pressure Equipment
Directive categories. It may also be used outside of the
Pressure Equipment Directive using sound engineering
practice (SEP) per table below. For information on the
current PED revision see Bulletin: D103053X012.
SIZE,
BODY
COnnECTIOn
Dn / nPS
MATERIAL
20, 25 /
All
3/4, 1
Specifications
Body Sizes (Inlet x Outlet) and
End Connection Styles
3/4, 3/4 x 1 and 1 NPT
All sizes available in Globe or Angle body
Allowable Inlet Pressures
Emergency: 10.3 bar / 150 psig
Maximum Operating Pressure: See Table 1
Allowable Outlet Pressures
Emergency (Casing): 1.7 bar / 25 psig
Maximum Operating Pressure to Avoid Internal
Parts Damage: 0.21 bar / 3 psi differential above
outlet pressure setting
Outlet Pressure Ranges
See Table 2
Proof Test Pressure
All Pressure Retaining Components have been
proof tested per Directive
Temperature Capabilities
-29 to 71°C / -20 to 160°F
1. The pressure/temperature limits in this installation guide and any applicable standard or code limitation should not be exceeded.
EnD
PED
PED
LIMITATIOn
CATEGORY
STYLE
All
- - - -
(1)
(1)
(1)
mm
3.2
4.8
6.4
9.5
13
Installation
Personal injury, equipment damage
or leakage due to escaping gas or
bursting of pressure-containing parts
might result if these regulators are
overpressured or installed where service
conditions could exceed the limits for
which the regulators were designed,
SEP
or where conditions exceed any
ratings of the adjacent piping or piping
connections. To avoid such injury or
damage, provide pressure-relieving or
pressure-limiting devices (as required
by the appropriate code, regulation or
standard) to prevent service conditions
from exceeding those limits.
Additionally, physical damage to a
regulator could cause personal injury
and property damage due to escaping
gas. To avoid such injury and damage,
install the regulator in a safe location.
A regulator may vent some gas to the
atmosphere in hazardous or flammable
gas service, vented gas might
accumulate and cause personal injury,
death or property damage due to fire or
explosion. Vent a regulator in hazardous
gas service to a remote, safe location
away from air intakes or any hazardous
location. The vent line must be protected
against condensation or clogging.
Table 1. Maximum Operating Inlet Pressure
MAxIMuM OPERATInG InLET
ORIfICE SIZE
PRESSuRE TO OBTAIn GOOD
REGuLATInG PERfORMAnCE
In.
1/8
3/16
1/4
3/8
1/2
WARnInG
!
Type HSR
psig
bar
8.6
125
6.9
100
4.1
60
2.1
30
1.4
20

Advertisement

loading

Summary of Contents for Emerson Fisher HSR Series

  • Page 1 Installation Guide Type HSR D103074X014 English – February 2014 Introduction Table 1. Maximum Operating Inlet Pressure MAxIMuM OPERATInG InLET This Installation Guide provides instructions for ORIfICE SIZE PRESSuRE TO OBTAIn GOOD installation, startup and adjustment. To receive a copy of REGuLATInG PERfORMAnCE psig the Instruction Manual, contact your local Sales Office or...
  • Page 2 Type HSR Before installing the regulator, check for damage Type HSR regulators provide internal relief that limits the which might have occurred in shipment. Also check total outlet pressure buildup over setpoint. This internal for dirt or foreign matter which may have accumulated relief may be adequate for the application, if not, provide in the regulator body or in the pipeline.
  • Page 3 Type HSR T80573 Figure 1. Type HSR Regulator Assembly Table 2. Outlet Pressure Ranges OuTLET PRESSuRE RAnGE SPRInG COLOR mbar In. w.c. 10 to 15 4 to 6 Orange 15 to 20 6 to 8 Yellow 20 to 25 8 to 10 Black 25 to 31 10 to 12.5...
  • Page 4 Technologies, Inc. All rights reserved. 02/19. McKinney, Texas 75070 USA Singapore 128461, Singapore The Emerson logo is a trademark and service mark of Emerson T +1 800 558 5853 T +65 6777 8211 Electric Co. All other marks are the property of their prospective owners.