3-2.
Service Menu List
3-2-1.
MAINTENANCE Menu List
Menu Item
Submenu Item
Test Saw
—
Black Shading
Setting
Channel
Sel
Auto BLK Shad
White Shading
Setting
Channel
Sel
Flare
G Flare
B Flare
R Flare
3-2-2.
RPN CORRECT Menu List
Note
Before executing the RPN CORRECT menu, check that the Inversion item on the PICTURE PROFILE menu is set to
Normal.
Menu Item
Submenu Item
Auto Detection
—
Correction Mode
—
Channel
—
Cursor
—
Cursor H Position
—
Cursor V Position
—
Cursor Next
—
MCC-3000MT
Choice
On, Off
On, Off
G, B, R
H Saw
–99 to +99
H Para
–99 to +99
V Saw
–99 to +99
V Para
–99 to +99
Execute, Cancel
On, Off
G, B, R
H Saw
–99 to +99
H Para
–99 to +99
V Saw
–99 to +99
V Para
–99 to +99
–99 to +99
–99 to +99
–99 to +99
Choice
Execute, Cancel
Concealment, Com-
pensation
G, B, R
On, Off
1 to 1920
1 to 1080
—
Function
Turns On or Off the Test Saw
Turns On or Off the black shading correction
Selects the channel (R-ch or G-ch or B-ch) to ex-
ecute black shading adjustment on (The present
setup values of H Saw, H Para, V Saw and V Para
for the selected channel are displayed automati-
cally)
Adjusts the black shading H Saw correction level
Adjusts the black shading H Para correction level
Adjusts the black shading V Saw correction level
Adjusts the black shading V Para correction level
Starts up the auto black shading correction
Turns On or Off the white shading correction
Selects the channel (R-ch or G-ch or B-ch) to ex-
ecute white shading adjustment on (The present
setup values of H Saw, H Para, V Saw and V Para
of the selected channel are displayed automatical-
ly)
Adjusts the white shading H Saw correction level
Adjusts the white shading H Para correction level
Adjusts the white shading V Saw correction level
Adjusts the white shading V Para correction level
Adjusts the G-ch flare correction level
Adjusts the B-ch flare correction level
Adjusts the R-ch flare correction level
Function
Starts up auto RPN
Selects the RPN correction mode that is used to
register or delete the manual registration
Selects and displays the channel to execute manual
registration or detection of RPN correction on
Turns On or Off the RPN correction point indicator
cursor
Displays and move the horizontal address of the
RPN correction point indicator cursor
Displays and move the vertical address of the RPN
correction point indicator cursor
Moves the RPN correction point indicator cursor
to the next RPN point
Continued
3-2