Technical Specifications

Technical Specifications
XM Plural-Component OEM Sprayer
Mixed ratio range
Ratio tolerance range
Flow rates
Minimum*
Maximum
Fluid viscosity range
Fluid filtration
Air inlet
Fluid inlets without feed kits
Ambient temperature range
Operating
Storage
Maximum fluid working pressure of mixed material
50:1
70:1
Maximum fluid temperature
Maximum pump inlet fluid feed pressure
Maximum pump air set pressure
50:1
70:1
Maximum air consumption at
100 psi (0.7 MPa, 7.0 bar) in scfm (m
Air supply pressure range
Noise dB(A)
Operating Pressure 70 psi (0.48 MPa, 4.8 bar)
† Sound power
‡ Sound pressure measured per ISO 3744
Operating Pressure 100 psi (0.7 MPa, 7 bar)
† Sound power
‡ Sound pressure measured per ISO 3744
Environmental conditions rating (indoor/outdoor use)
Altitude Rating
Maximum relative humidity
Pollution degree
Installation category
* Minimum flow rate is dependent on the material being sprayed and its mixing capability. Test your material specific
to the flow rate.
28
200-20,000 cps (heavier viscosities can be mixed using heat,
60 mesh, (238 micron) standard on pump outlets
(filter assembly not included on some models)
^
3/min.)
Altitudes up to 13,123 ft
To 99% up to 130 °F
US
1:1-10:1 (in 0.1 increments)
+/- 5%
1 qt./min.
3 gal./min.
circulation, and/or pressure feeding)
1 npt(f)
1 1/4 npt(m)
32-135 °F
30-160 °F
5200 psi
6300 psi
160 °F
250 psi
100 psi
90 psi
70 scfm per gpm (1.96 m^3min. per lpm)
50-150 psi
84.8 dB(A)
95.1 dB(A)
91.7 dB(A)
102.0 dB(A)
11
2
Metric
0.95 liter/min.
11.4 liter/min.
0-57 °C
-1-71 °C
35.8 MPa, 358 bar
43.5 MPa, 435 bar
71 °C
1.7 MPa, 17 bar
0.68 MPa, 6.8 bar
0.62 MPa, 6.2 bar
0.35-1.0 MPa, 3.5-10.3 bar
Altitudes up to 4000 m
To 99% up to 54 °C
313292K