11. Installation
Viewing the typical installation
A typical installation will be similar to the one shown below.
Maximum pipe height
Maximum pipe length
**09*******
**12*******
CAUTION
• For the product that uses the R-32 refrigerant, Install the indoor unit on the wall 1.8 m or higher from the floor.
※ In case you want more information about the controllers and accessories, please refer to the Controller and
Accessory TDB on pvi.Samsung.com site or Global Partner Portal site.
Evaporator/
fancoil (indoor)
Model
Minimum
3
Outdoor Unit
Outer wall
Indoor Unit
Cut insulation to have
rainwater drained
Refrigerant lines,
electric, and drain
Compressor/
condenser
(outdoor)
Pipe length
Maximum
Standard for factory charge
15
5
Make a U-trap (A) on the pipe (which is connected to
the indoor unit) at outer wall and cut the bottom part of
the insulation (about 10 mm) to prevent rainwater from
C
A
UTION
C
A
UTION
getting inside through the insulation.
Make at least one round to
reduce noise and vibration.
The actual units may look different from
the images depicted here.
(Unit : m)
Pipe height
Maximum
8