Technical data
Electrical data
Range
Impedance
Polarization
VSWR (standing wave ratio)
Power
Interfaces
Plug connection
Mechanical specifications
Material
Color
Tightening torque (at room temperature)
Permitted ambient conditions
Ambient temperature
Degree of protection
Shock resistant to EN 60068-2-27
Vibrations according to EN 60068-2-6
Design, dimensions and weight
Dimensions (H x W x D)
Weight
Standards, specifications, approvals
Proof of suitability
MTBF
The values differ for different dimensions/materials of the mounting surface.
1)
The values for shock and vibration are maximum values and must not be applied continuously.
2)
28
•
ETSI
•
FCC
•
During operation
•
During transportation and storage
•
ETSI
•
FCC
See section "Maximum read/write ranges
(Page 25)"
50 Ω
Linear
≤ 2:1
•
≤ 2 W
•
≤ 1 W
30 cm coaxial cable with RP-TNC connector
(for connection of the antenna cable)
Pocan
TI-Grey
≤ 2 Nm
•
-20 ... +70 °C
•
-40 ... +85 °C
IP65
(IP rating is not investigated by UL)
50 g
2)
20 g
2)
75 x 75 x 20 mm
100 g
•
CE (ETSI EN 302208)
•
FCC (Title 47, Part 15.247), cULus
1190 years
Operating Instructions, 11/2020, C79000-G8976-C601-01
6GT2812-2EA0x
SIMATIC RF622A