Delta PJH Series Instruction Manual

Advertisement

Quick Links

Instruction Manual
1.
Safety Instructions
The device is not recommended to be placed on low thermal conductive surface, for example, plastics.
For safety reason, please ensure the mounted device is kept at ≥ 8mm safety distance for D1 from other components
and equipments. Please insert an insulation sheet between the system and product, if the safety distance is < 8mm for D2
(Refer to Fig. 2.1)
Installation of forced air, to ensure sufficient air flow, always maintain a distance and air flow direction
as recommended in Fig. 4. while the device is in operation.
Note that the device can become very hot depending on the ambient temperature and load of the power supply.
Do not touch the device while it is in operation or immediately after power is turned OFF. Risk of burning!
Do not touch the terminals while power is being supplied. Risk of electric shock.
Prevent any foreign metal, particles or conductors to enter the device through the openings during installation. It can cause:
Electric shock; Safety Hazard; Fire; Product failure.
For Protection against shock to Class I with PE (protection earth) and Class II with or without FG (functional ground) product,
the two mounting holes (marked Ⓑ in Fig. 1) need to be connected together to the system's protective earth or functional ground.
Pollution degree and EMC performance with different connections please refer to product datasheet.
Warning: The power supply must be mounted by metal screws onto a grounded metal surface. It is highly recommended that
the Earth terminal on the connector be connected to the grounded metal surface.
2.
Device Description
Refer ot Fig .1.:
PIN
Description
No.
Input connector (CN1)
1
2
Control and Vsb Connector (CN101)
1
2
3
4
5
6
7
8
9
10
Output Connector (CN103)
1
Output Connector (CN102)
1
DC voltage adjustment potentiometer
DC OK control LED (Green)
Internal fuse is a time lag type, rated 5A / 250Vac.
Walter: Type ICP Conquer: Type PTU TR
3.
Installation of the Device
The unit is protected with internal fuse (not replaceable) at L pin and it has been tested and approved on
20A (UL) and 16A (IEC) branch circuits without additional protection device.
Refer to Fig .1.:
Mounting holes for the power supply.
1)
Mounting holes should be connected to the system's protective earthing (PE) for Class I or
fuctional ground (FG) for Class II.
1)
This surface belongs to customer's end system or panel where the power supply is mounted.
1) Note: 4 × Ø3.5 Mounting Holes; Ø5.5 Max Dimension of Screw Head. Recommended mounting torque for tightening: 4-8Kgf.cm.
REV.00
Function
Function
► PJH-36V300WBB☐
► PJH-36V300WBC☐
Neutral (N)
Neutral (N)
Line (L)
Line (L)
Netutral (N)
Netutral (N)
5V
12V
SB
SB
GND
GND
5V
12V
SB
SB
GND
GND
Remote On/Off
Remote On/Off
GND
GND
Power Good
Power Good
Remote Sense of V1(-)
Remote Sense of V1(-)
Remote Sense of V1(+)
Remote Sense of V1(+)
GND
GND
V1(+)
V1(+)
1
2
7
Fig. 1. Device Description
PSU
Fig. 2. Assembly Reference
C
A
B
CN1
CN1
D2*
CN1
Fig. 3. Mounting Orientations
PJH-36V300WB☐
3
4
1
10
CN1
D1* ≥ 8mm
E
D
CN1
F
CN1
CN1
D2*
D2* ≥ 30mm
www.DeltaPSU.com

Advertisement

loading

Summary of Contents for Delta PJH Series

  • Page 1 Instruction Manual PJH-36V300WB☐ Safety Instructions • The device is not recommended to be placed on low thermal conductive surface, for example, plastics. • For safety reason, please ensure the mounted device is kept at ≥ 8mm safety distance for D1 from other components and equipments.
  • Page 2 Instruction Manual PJH-36V300WB☐ Power Derating Curve (Refer to Fig .4) PJH-36V300WBC☐(y) PJH-36V300WBB☐(y) Forced Air: 10CPM Forced Air All orientations 300W = 36V/8.3A. 12V/0.5A 300W = 36V/8.3A. 5V/1.2A Forced air cooling > 50°C de-rate power by 2.5% / °C 150W = 36V/4.2A. 12V/0A 150W = 36V/4.2A.
  • Page 3 PJH-36V300WB☐ 使用手册 1. 安全须知 • 不建议将电源置于低热传导表面诸如塑料之上。 • 出于安全原因,敬请确保安装的电源与其他任何部件或设备保留 ≥ 8mm 之安全距离 (D1),如D2安 全距离 < 8mm(参见图2.1),请在系统与产品间插入绝缘板。 • 安装时为确保强制通风所需的充足气流,电源运行时应始终留出足够空间,气流方向如图4 建议。 • 注意,由于电源和负载工作,环境温度可能过高,电源可能发烫。电源运行时或电源关闭之初切勿触 碰,小心烫伤! • 电源供电时切勿触碰电源端口,小心电击。 • 安装过程中谨防任何外来金属、颗粒或传导材料从开口处进入设备,以免引发电击、安全隐患、火灾 或产品故障。 • 为使设备在连接保护地线 (PE) 状态下达到防冲击 Class I标半年准,或在配备与不配备FG(功能接 地)产品状态下达到 Class II 标准,两个安装孔(图1 标记处)需一同连接至系统保护地线或功能 Ⓑ 接地。不同连接之防污染等级与EMC性能敬请参见产品技术参数表。 • 警示:电源供应器必须使用金属螺丝安装于接地金属表面之上,最好将连接器接地端口连接至接地金 属表面。...
  • Page 4 PJH-36V300WB☐ 使用手册 4. 功率降额曲线 (参见图4) PJH-36V300WBC☐(y) PJH-36V300WBB☐(y) Forced Air: 10CPM Forced Air All orientations 300W = 36V/8.3A. 12V/0.5A 300W = 36V/8.3A. 5V/1.2A 强制冷却 > 50°C de-rate power by 2.5% / °C 150W = 36V/4.2A. 12V/0A 150W = 36V/4.2A. 5V/0A (300W @ 50°C, 225W @ 60°C, 150W @ 70°C) 240W = 36V/6.6A.

This manual is also suitable for:

Pjh-36v300wb seriesPjh-36v300wbcaPjh-24v300wbca