Chapter 6 Appendix; Appendix A: Technical Indexes - UNI-T UTD2000M Operating Manual

Digital storage oscilloscope
Table of Contents

Advertisement

 
 
                                                                                                                                                                                          UTD2000M User Manual 
 
Appendix A: Technical Indexes 
Unless otherwise stated, all technical indexes are applicable to probes with attenuation switch set to be 10× 
and UTD2102CM series digital storage oscilloscopes. Those digital storage oscilloscopes must first comply with 
the following two conditions in order to meet those specification standards.           
■The unit must be running under a specific operating temperature for more than 30 minutes.       
■If the change in operating temperature reaches or exceeds 5℃, system function menu has to be opened to 
execute "auto calibration" program. Other than those marked with the word "typical", the effectiveness of all 
specifications are guaranteed.               
 
Technical Indexes 
Sampling Mode   
Sampling 
    Real‐time Sampling 
Mode 
Sampling 
Single Channel: 1GS/s; Dual Channel (both) : 
Rate 
500MS/s   
Average 
When all channels reach N times of sampling simultaneously, wherein "N" can be any number 
Value 
among 2, 4, 8, 16, 32, 64, 128, 256 and 512.   
 
Input 
Input Coupling 
Input Impedance 
Probe Type 
Probe 
Bandwidth
Probe 
Attenuation 
100MHz   
Coefficient 
Bandwidth
Setting       
100MHz 
Maximum Input Voltage 
Time Delay Between Channels (Typical) 
 
 
 
 
 
 
 
 
Chapter 6 Appendix   
DC, AC, GND 
Bandwidth≤100MHz  1±2%ΜΩ,Parallel connection with 24±3pF
Bandwidth>100MHz   1±2%ΜΩ,Parallel connection with 18±3pF
Voltage, Current (Bandwidth  ≤100MHz) 
Voltage (Bandwidth>100MHz) 
1×, 10×, 100×, 1000×  or user‐defined 
 
1×、10×、100×、1000× 
 
400V(DC+AC Peak Value, Input Impedance 1MΩ) 
50ps 