661693-UIM-E-1212 1. Install this air handler only in a location and position as specified in SECTION III of these instructions. 8. Installing and servicing heating/cooling equipment can be hazard- 2. Always install the air handler to operate within the air handler’s ous due to the electrical components.
Page 4
661693-UIM-E-1212 HORIZONTAL LEFT OR RIGHT UPFLOW Use an appropriate tool to pry out water deflector with two or three s- clips from the vertical drain pan, see Figure 4. Relocate the deflector HEAT with s-clips on the Horizontal Drain Pan lined up to the coil support bracket.
Page 5
661693-UIM-E-1212 DUCT CONNECTIONS Equipment should never be operated without filters. Use 1/2" screws to connect ductwork to bottom of unit. Longer screws HORIZONTAL SUSPENSION will pierce the drain pan and cause leakage. If pilot holes are drilled, drill only though field duct and unit bottom flange. For suspension of these units in horizontal applications, it is recom- mended to use angle steel support brackets with threaded rods, sup- Air supply and return may be handled in one of several ways best...
Page 6
661693-UIM-E-1212 Please refer to Outdoor Unit Tech Guide to verify which TXV is installed 3. Wrap a water soaked rag around the coil connection tubes inside in this coil and that this is a valid system match for the AC or HP unit the cabinet to avoid damaging the TXV bulb.
661693-UIM-E-1212 SECTION IV: ELECTRIC HEATER SECTION V: LINE POWER CONNECTIONS INSTALLATION Power may be brought into the unit through the supply air end of the If the air handler requires electric heat, install the electric heat kit unit (top when unit is vertical) or the left side panel. Use the hole appro- according to the installation instructions included with the kit.
661693-UIM-E-1212 SECTION VI: LOW VOLTAGE CONTROL SECTION VII: BLOWER SPEED CONNECTIONS CONNECTIONS The 24 volt power supply is provided by an internally wired low voltage Adjust blower motor speed to provide airflow within the minimum and transformer which is standard on all models, However, if the unit is con- maximum limits approved for evaporator coil, electric heat and outdoor nected to a 208 volt power supply, the low voltage transformer must be unit.
Page 9
661693-UIM-E-1212 TABLE 4: ELECTRICAL HEAT: MINIMUM FAN SPEED Air Handler Models Nom. kW Heater Kit Models @240V AHR18B AHR24B AHR30B AHR36B AHR42C AHR48D AHR60D 6HK(0,1)6500206 2.4kW 6HK(0,1)6500506 4.8kW 6HK(0,1)6500806 7.7kW 6HK(0,1)6501006 9.6kW High High 6HK06501025 6HK(1,2)6501306 12.5kW High High High High 6HK(1,2)6501506 14.4kW...
Page 10
661693-UIM-E-1212 TABLE 6: ELECTRICAL DATA FOR SINGLE SOURCE POWER SUPPLY: 208/230-1-60 (Continued) Field Wiring Heater Heater Air Handler Models Amps Min. Circuit Ampacity MOP. Min Wire Size (AWG) Models @240V 208V 230V 208V 230V 208V 230V 6HK(0,1)6500206 10.0 14.6 16.3 6HK(0,1)6500506 20.0 25.4...
Page 11
661693-UIM-E-1212 TABLE 8: ELECTRICAL DATA FOR SINGLE SOURCE POWER SUPPLY - 208/230-3-60 Field Wiring Heater Heater Air Handler Models Amps Min. Circuit Ampacity Min. Wire Size (AWG) Models @ 240V 208V 230V 208V 230V 208V 230V 6HK06501025 23.1 26.8 30.7 AHR24B 6HK06501525 34.6...
661693-UIM-E-1212 SECTION XII: START UP SHEET Residential Air Handler Print Form Reset Form with Electric Heat Start-Up Sheet Proper start-up is critical to customer comfort and equipment longevity Start-Up Date Company Name Start-Up Technician Owner Information Name Address Daytime Phone City State or Province Zip or Postal Code...
Page 17
661693-UIM-E-1212 Electric Heat (Complete all that apply) Electric heat kit - Model number Serial number Rated KW Heater 1 Heater 2 Heater 3 Measured Amperage Heater 4 Heater 5 Heater 6 Number of elements Heater 1 Heater 2 Heater 3 Measured Voltage Heater 4 Heater 5...