York AHP18 THRU 60 Technical Manual

York AHP18 THRU 60 Technical Manual

Single piece air handlers for use with split-system cooling & heat pumps
Hide thumbs Also See for AHP18 THRU 60:

Advertisement

TECHNICAL GUIDE
SINGLE PIECE AIR HANDLERS
FOR USE WITH SPLIT-SYSTEM
COOLING & HEAT PUMPS
MODELS: AHP18 THRU 60 AND SHP48 THRU 60
Due to continuous product improvement, specifications
are subject to change without notice.
Visit us on the web at www.york.com
Additional rating information can be found at
www.ari.org/aridirectory.
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
ISO 9001
Certified Quality
Management System

DESCRIPTION

This fan coil line offers the ultimate in application flexibility.
The AHP (non-variable speed motor) models can be ordered
upflow only or as multi-position. The multi-position model can
be installed in downflow, upflow, horizontal right or left without
the need for additional field installed kits.
The SHP 48 & 60 models are upflow only models designed
into a shorter cabinet than the AHP version, for those special
applications where reduced height is required.
All UPG air handlers and coils utilize a TXV to provide our
customers with the optimum performance and refrigerant
control required for 13+ systems. Air handlers can be ordered
with a R22 TXV factory installed that can be easily converted
to R410A by changing the bolt-on TXV. Air handlers are also
available with "Flex-coils" without a factory installed metering
device. For added flexibility, an R22 or R410A TXV can be
field installed to meet your refrigerant choice.

FEATURES

Thermal Expansion Valve - Provides the ultimate refrigerant
control required for today's high efficient product. The UPG
bolt-on TXV provides the added flexibility to convert the air
handler to the required refrigerant. The UPG TXV is a true
bolt-on which does not require brazing to replace or install.
TM
MicroBlue
Coated Fins - All air handler coils are treated
TM
with the MicroBlue
hydrophilic coating to enhance the
removal of condensate during the refrigeration cycle and
reduce the possibility of water blow-off. The MicroBlue
coating also reduces the growth of germ causing microbes
for a healthier home environment.
Insulated Cabinet - All air handler cabinets are thermally
insulated with 1" foil faced insulation (R-4.2) to prevent
sweating. For applications in extreme humidity conditions an
optional, field installed, external insulating wrap kit is also
available.
Durable Finish Inside and Out - Air handler casings are
made of pre-painted galvanized steel which provides a better
paint to steel bond that resists corrosion and rust creep. All
internal coil sheet metal parts are made of G90 pre-painted
steel (i.e. triangular plates, top plates, horizontal supports
etc). Coil header plates are not painted due to the brazing
process during production. The coil header plates are treated
after the brazing process with a corrosion resistant spray to
reduce the probability of rust.
High Efficiency - 5 ton unit has high efficiency DC motor.
New 4 HK Heat Kit - Installation friendly, easy service, more
robust, unique to new design.
255029-YTG-J-1007
TM

Advertisement

Table of Contents
loading

Summary of Contents for York AHP18 THRU 60

  • Page 1 TECHNICAL GUIDE SINGLE PIECE AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: AHP18 THRU 60 AND SHP48 THRU 60 ISO 9001 Certified Quality Management System Due to continuous product improvement, specifications are subject to change without notice.
  • Page 2 DIMENSIONS BLOWER COMPARTMENT DRAIN CONNECTIONS REFRIGERANT CONNECTIONS 7-11/32” 1-1/2” FILTER ACCESS DIMENSIONS Models Height Width AHP18B**(N,H)21 17.5 AHP24B**(N,H)21 17.5 AHP30B**(N,H)21 17.5 AHP36C**(N,H)21 AHP42C**(N,H)21 AHP48D**(N,H)21 24.5 SHP48D**N21 24.5 AHP60D**(N,H)21 24.5 SHP60D**N21 24.5 1. Actual size (Conduit size). COIL TECHNICAL DATA Refrig. Models Application Conn.
  • Page 3 255029-YTG-J-1007 COOLING CAPACITY Models Rated CFM AHP18B2A(N,H)21 AHP24B2A(N,H)21 AHP30B2A(N,H)21 1050 AHP36C2A(N,H)21 1200 AHP42C2C(N,H)21 1400 AHP48D2C(N,H)21 1600 SHP48D2CN21 AHP60D2C(N,H)21 1850 SHP60D2CN21 Unitary Products Group MBH@ Evaporator Temperature and Corresponding Pressure °F / PSIG Entering Air °F (Dry / Wet Bulb) 35 / 61.5 FULL-CASED “A”...
  • Page 4 ACCESSORIES Refer to Price Manual for specific model numbers. TXV Kits - TXV kits are available for “Flex-coil” applications and converting R22 to R410A or as a service replacement. All kits are bolt-on and require no brazing to install. Non-Combustible Bases - A combustible floor base acces- sory is available, if required by local codes, when the air han- dler is installed in the downflow position on a combustible material.
  • Page 5 255029-YTG-J-1007 AIR FLOW DATA - 60 Hz MODELS Blower Models Motor Speed High AHP18B**(N,H)21 Medium High AHP24B**(N,H)21 Medium High AHP30B**(N,H)21 Medium High AHP36C**(N,H)21 Medium High AHP42C**(N,H)21 Medium High AHP48D**(N,H)21 Medium SHP48D**N21 High / #1 Medium High / #2 AHP60D**(N,H)21 Medium / #3 SHP60D**N21 Medium Low / #4 Low / #5...
  • Page 6 PHYSICAL & ELECTRICAL DATA Models Blower - Diameter x Width Motor Nominal RPM Voltage Amps Full Load (230) Type Size Filter Permanent Type Kit Shipping / Operating Weight (lbs.) - AHP*****N1 Shipping / Operating Weight (lbs.) - AHP*****H1 Models Blower - Diameter x Width Motor Nominal RPM Voltage...
  • Page 7 255029-YTG-J-1007 ELECTRICAL DATA - 208/230-1-60 Heater Models Models* 4HK*6500206 AHP18B**(N,H)21 4HK*6500506 4HK*6500806 4HK*6500206 4HK*6500506 AHP24B**(N,H)21 4HK*6500806 4HK*6501006 4HK16501306 4HK*6500506 4HK*6500806 4HK*6501006 AHP30B**(N,H)21 4HK16501306 4HK165N1506 4HK*6500506 4HK*6500806 AHP36C**(N,H)21 4HK*6501006 4HK16501506 4HK16501806 4HK*6500506 4HK*6500806 4HK*6501006 AHP42C**(N,H)21 4HK16501506 4HK16501806 4HK16502006 4HK*6500506 4HK*6500806 4HK*6501006 AHP48D**(N,H)21 SHP48D**N21 4HK16501506...
  • Page 8 ELECTRICAL DATA (FOR SINGLE SOURCE POWER SUPPLY) - COPPER WIRE 208/230-1-60 Heater Models Models* 4HK*6500206 AHP18B**(N,H)21 4HK*6500506 4HK*6500806 4HK*6500206 4HK*6500506 AHP24B**(N,H)21 4HK*6500806 4HK*6501006 4HK16501306 4HK*6500506 4HK*6500806 AHP30B**(N,H)21 4HK*6501006 4HK16501306 4HK165N1506 4HK*6500506 4HK*6500806 AHP36C**(N,H)21 4HK*6501006 4HK16501506 4HK16501806 4HK*6500506 4HK*6500806 4HK*6501006 AHP42C**(N,H)21 4HK16501506 4HK16501806 4HK16502006...
  • Page 9 255029-YTG-J-1007 ELECTRICAL DATA (FOR MULTI SOURCE POWER SUPPLY) - COPPER WIRE 208/230-1-60 Heater Models Models AHP24B**(N,H)21 4HK16501306 40.9 / 47.0 4HK16501306 41.6 / 47.9 AHP30B**(N,H)21 4HK165N1506 45.8 / 52.8 4HK16501506 47.5 / 54.5 AHP36C**(N,H)21 4HK16501806 43.9 / 50.3 4HK16501506 47.6 / 54.8 AHP42C**(N,H)21 4HK16501806 44.0 / 50.6...
  • Page 10 ELECTRICAL DATA (FOR SINGLE SOURCE POWER SUPPLY) - COPPER WIRE 208/230-3-60 Heat Kit - Models Three Phase AHP24B**(N,H)21 4HK06501025 4HK06501025 AHP30B**(N,H)21 4HK065N1525 4HK06501025 AHP36C**(N,H)21 4HK06501525 4HK06501025 AHP42C**(N,H)21 4HK06501525 4HK06501825 4HK06501025 AHP48D**(N,H)21 4HK06501525 SHP48D**N21 4HK06501825 4HK06501025 AHP60D**(N,H)21 SHP60D**N21 4HK06501525 1. O.C.P. = Over Current Protection device, must be HACR type Circuit Breaker or Time Delay fuse. 2.
  • Page 11 255029-YTG-J-1007 COOLING MODELS WITH ELECTRIC HEAT WIRING MA SERIES - Air Handler Control Wiring Typical A/C - Cooling only Applications AIR HANDLER THERMOSTAT BOARD Y / Y2 X / L COOLING MODELS WITH ELECTRIC HEAT WIRING * Optional dehumidification humidistat switch contacts open on humidity rise. Notes: 1.
  • Page 12 TYPICAL APPLICATIONS UPFLOW Subject to change without notice. Printed in U.S.A. Copyright © by Unitary Products Group. 2007. All rights reserved. Unitary Products Group DOWNFLOW 5005 York Drive HORIZONTAL RIGHT HORIZONTAL LEFT 255029-YTG-J-1007 Supersedes: 255029-YTG-I-0507 Norman 73069...

Table of Contents