Replacing Lithium Battery - Sony PXW-X500 Service Manual

Solid-state memory camcorder
Hide thumbs Also See for PXW-X500:
Table of Contents

Advertisement

1-8.

Replacing Lithium Battery

The FP-208 board (inside panel assembly) is equipped with the lithium battery for time of the internal clock.
If the message "Backup Battery End Please Change" appears in the LCD monitor or viewfinder, this battery must be
exchanged.
After replacing it, refer to "Using the Unit for the First Time" of the operating instructions, and set the date and time of
the internal clock.
Part No.
1-528-174-72
Replacing procedure
Note
In replacing, ensure that the battery is installed with "+" and "–" poles connected to the correct terminals. Improper
connection may cause an explosion or leakage of fluid, resulting in injury or damage to surrounding properties.
1.
Loosen the four screws with stopper and remove the inside panel.
Screws with stopper
Screws with stopper
2.
Turn over the FP shield cover and replace the lithium battery (CR2032) on the FP-208 board.
FP shield cover
3.
Attach the inside panel assembly by reversing the steps of removal.
PXW-X500
Name
Lithium Battery (CR2032 type)
Inside panel assembly
Lithium battery
(CR2032)
Usage
For internal clock
1-28