Chapter 5 Troubleshooting And Others - Delta AS-BF Series Operating Manual

Communicating area sensor
Table of Contents

Advertisement

Chapter 5
Troubleshooting and Others
Troubleshooting
Indicator
Light is off
Irregular flashing of red/green
light
Blue/green/red lights are lit
simultaneously
Only blue light is lit, and green
light is not lit; red light is lit when
shielded
Orange light
Red/green lights are lit, and
blue lit is not lit
Operating Manual for Communicating Area Sensor

Chapter 5 Troubleshooting and Others

Cause
Poor power contact
Poor beam alignment
Electrical interference
Light source
interference
Over-current
Power saving setting
Wiring error, or input
voltage exceeds
specifications
Abnormal internal
signal/voltage
Abnormal number of
beams
Inspection method
Check the power connection and whether
or not the connector pin is bent
Whether it be switched to green light with
near-distance alignment
Check the module and bracket installed flat
Check whether mounting method is
susceptible to vibration
Check if the shield is connected to a clean
ground.
Has external high power machine
shutdown been improved?
Is there any external glare affecting device?
Installation of multiple light curtains should
use transmitter/receiver staggered format
Check load at output end
Check output mode setting
Turn off power saving setting
Check if wire connection is normal
Check if input voltage is within range
Contact DELTA service center
Beam number setting error, or abnormal
number of internal beams Contact DELTA
service center
5-1