Chapter 4 Communication Protocol

4.2 Description of Communication Function

Example 1. Change the format of Modbus communication
Change the communication format to address 2, Baud Rate to 19200, and format to 8,E,1; the procedure
is as shown below
Sequence of executed action
Change address to 2
Change Baud Rate to 19200
Change format to 8,E,1
Execute communication confirmation
action
Example 2. Floating blanking function (limited to ON/OFF operation mode)
Note: Takes effect immediately after setting. Disconnect product output contact from the host before
setting, in order to prevent malfunction and damage.
Description: Only when the number of shielded beams exceeds the set value will the output be ON.
Setting: Default value 0 indicates turn off floating blanking function; maximum value cannot exceed half
the products number of beams.
Executed action
Set floating blanking number to 3
Example 3. Fixed blanking function (Limited to ON/OFF and measurement operation mode)
Note: Takes effect immediately after setting. Disconnect product output contact from the host before
setting, in order to prevent malfunction and damage.
Description: Turn off designated beam detection. Non-shading/shading status of this beam will not affect
the output action.
Setting: Default 1 indicates that beam detection is turned on; 0 indicates that beam detection is turned off.
Executed action
Turns off detection for beams 1-4.
Example 4. Interlock/restart interlock function (limited to ON/OFF operation mode)
Note: Takes effect immediately after setting. Disconnect product output contact from the host before
setting, in order to prevent malfunction and damage.
Description: Once shading occurs, output remains in OFF state; after full non-shading takes place again,
reset interlock function is executed, and only then is ON state restored at output.
Setting: Default 0 indicates that interlock function is turned off; 1 indicates that interlock function is turned
on.
Executed action
Turn on interlock function
4-10
ASCII
:01060081000276
:01060082000374
:01060083000373
:01060084000174
ASCII
:01060085000371
ASCII
:0106003000F0D9
ASCII
:01060086000172
Operating Manual for Communicating Area Sensor
RTU
01 06 00 81 00 02 58 23
01 06 00 82 00 03 69 E3
01 06 00 83 00 03 38 23
01 06 00 84 00 01 08 23
RTU
01 6 00 85 00 03 D8 22
RTU
01 06 00 30 00 F0 89 81
RTU
01 06 00 86 00 01 A9 E3