Replacement Parts - Marshall Amplification DH1-1010 Series Owner's Manual

Heated holding unit
Table of Contents

Advertisement

OWNER'S MANUAL
MODEL DH1-1010 SERIES – HEATED HOLDING UNIT
Part Replacement Time: 43 min
502978 - Blanket, Heater 240V
These heating blankets are used in the bottom
heaters of each deck. A defective blanket could
cause non-heating of the associated deck bottom
heater and therefore an undesired change in the
food product quality.
Part Replacement Time: 19 min
174837 – Control, Deck 2
Time/temperature
controller
programmed according to customer's specific
settings. Replace if the controller is not operating
according to specs or if it won't turn on when
8.5VDC is supplied to it.
Part Replacement Time: 9 min
171132 - Fan, Asby
Fan used inside control box to cool electrical
components.
Failure can cause electrical
components to overheat and fail or alter food
product quality. Should be replaced if worn or
damaged.
174830 RV120817
Copyright © 2017 Marshall Air Systems, Inc.
All Rights Reserved.

REPLACEMENT PARTS

Part Replacement Time: 6 min
502091 - Connector, Strain Relief
Strain relief used with main power cord and
should be replaced if missing or damaged.
Part Replacement Time: 7 min
504264 - Cord, 12/4 NEMA L14-20P
factory
pre-
Main power cord. Damaged cord can cause unit
to stop operating and should be replaced.
Part Replacement Time: 10 min
504318 - Power Supply
The 120VAC to 8.5VDC power supply is used to
power the time/temperature controllers.
defective power supply could cause all controllers
to not turn on when powered.
Time/temperature
programmed according to customer's specific
settings. Replace if the controller is not operating
according to specs or if it won't turn on when
8.5VDC is supplied to it.
Top heater element. Two elements are used for
each top heaters. Bad element could cause non-
heating of the associated deck top heater and
therefore an undesired change in the food
product quality.
SSRs are used to turn on and off power delivered
A
to their associated heater once it reaches
temperature set point.
associated heater to excessively rise above set
point and might cause permanent damage to it.
8
Part Replacement Time: 19 min
174826 – Control, Deck 1
controller
factory
156008 – Element, 208V Rebend
Part Replacement Time: 8 min
504023 - Relay, Solid State 25A
Failure will cause the
pre-

Advertisement

Table of Contents
loading