LDS 3000
Operators manual
Receiver side
4. Mount the receiver back again and twist-mount the cross hair
instead of the detector module. Align with the four bolts on the
flange, the light dot must be centred in the inner ring of the cross
hair.
Receiver side
CD 3002 is now aligned and the holder for the fibre connector and the de-
tector module should be mounted in their places.
Finally, instrument air, or which ever method is used to protect the opti-
cal surfaces, should be connected to the appropriate inlets both at the
transmitter and receiver side of the sensor.
The mechanical stability of the sensor mechanics is sufficient to allow
dismounting (the quick connection) of both the receiver and the trans-
mitter. This means that cleaning of the lenses does not require re-align-
ment of the sensor.