Spray Pattern Adjustment - Graco GUSMER D Series Instructions Manual

Table of Contents

Advertisement

Spray Pattern Adjustment

Spray Pattern Adjustment
This adjustment may create a large mass "bun" of
urethane foam. Very high temperatures created by
chemical reaction inside a bun may not dissipate after
outside surface has cooled. A large bun may continue
to react for several hours after spraying until flash
(burning) point of foam is reached. Always break
buns into smaller pieces so heat can escape.
1. Check valving rod clearance in closed position. Rod
should extend approximately 1/32 in. (1 mm)
beyond tip of mixing chamber. If it does not, see
Valving Rod Adjustment procedure, page 20.
F
. 10 Valving Rod (Closed Position)
IG
2. Adjust valving rod travel to initial setting.
a. Loosen friction lock. Turn valving rod
adjustment screw clockwise until it stops.
b. Turn valving rod adjustment screw 11 times
counterclockwise.
3. Locate point of valving:
a. Aim gun at disposable target.
b. Dispense short (1 second) bursts toward target
while simultaneously withdrawing valving rod
adjustment screw from retainer case by 1/4-turn
increments in counterclockwise direction.
14
1/32 in.
c. Point of valving is reached when chemical
stream mists as shown in F
F
. 11 Point of Valving
IG
4. Adjust spray pattern. Note position of notch in
hexhead of adjustment screw, then back screw out
counterclockwise the number of turns specified in
Table 1. Notice spray pattern opens as adjustment
is made (F
. 12).
IG
F
. 12 Opening Spray Pattern
IG
. 11.
IG
311320K

Advertisement

Table of Contents
loading

Table of Contents