Trouble Conditions; Alarm Memory; Door Chime (Entry/Exit Beeps) - ADT PowerSeries SCW9045-433 User Manual

Self contained wireless alarm system v1.0
Table of Contents

Advertisement

To select a Bypass Group when arming the system:
1. Press
, then your [access code] (if necessary).
2. Press
. The next time the system is armed, the zones in this group will be bypassed.
3. To exit bypassing mode and return to the Ready state, press
NOTE: A Bypass Group is only recalled if the system is armed/disarmed after programming the by-
pass group.
NOTE: This feature is not to be used in UL Listed installations.

Trouble Conditions

When a trouble condition is detected, the Trouble ( ) indicator will turn on, and the keypad will
beep every 10 seconds. Press the
dition. The Trouble ( ) indicator will flash. Use the
Trouble
Condition
Service Required
(Press [1] for more
information)
Loss of AC Power
Telephone Line
Fault
Failure to
Communicate
Sensor (or Zone)
Fault
Sensor (or Zone)
Tamper
Sensor (or Zone)
Low Battery
Loss of Time & Date

Alarm Memory

When an alarm occurs, the Alarm Memory Message will be displayed. To view which sensor(s) gener-
ated the alarm, press
For the system keypad use the
Press
to exit. To clear the memory, arm and disarm the system.
If an alarm sounded while armed, the system will automatically go to alarm memory when you dis-
arm the system. In this instance, you should approach with caution, as the intruder may still be within
the building/premises.

Door Chime (Entry/Exit Beeps)

To turn the door chime function on or off, press and hold the Chime key for 2 seconds or press
.
key to silence the beeps. Press
Indicates Low Battery, System Trouble, System Tamper or
RF Jam detected.
If the building and/or neighbourhood has lost electrical
power, the system will continue to operate on battery for
several hours.
The system has detected that the telephone line is dis-
connected.
The system attempted to communicate with the moni-
toring station, but failed. This may be due to Telephone
Line Fault.
The system is experiencing difficulties with one or more
sensors on the system. Press [5] to display zone(s).
The system has detected a tamper condition with one or
more sensors on the system. Press [6] to display zone(s).
If the system has been equipped with wireless sensors,
one or more has reported a low battery condition. Press [7]
to display the zone(s). Press [7] again to display WLS keys.
If complete power was lost (AC and Battery), the time
and date will need to be re-programmed. Press [*]
.
scroll keys to view the sensors in alarm memory.
keys to view troubles.
Comments
6
.
to view the trouble con-
Action
Call for service
Check AC
connection
Call for service
Call for service
Call for service
Call for service
Call for service
Call for service
Re-program Time &
Date (page 4)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Powerseries scw9047-433

Table of Contents