Dimplex XLF50 Owner's Manual page 10

Hide thumbs Also See for XLF50:
Table of Contents

Advertisement

Available languages

Available languages

Fireplace Installation
past the flame panel, so as
not to be visible after final
assembly.
• Continue to the final assembly
instructions.
120V Installation - Wall Switch
!
NOTE:
Use a single pole,
single throw (On/Off) wall switch
that is rated for a minimum of
15 amps.
!
NOTE: The unit is designed
to be hardwired to a power
source and should not have
a cord installed to allow the
unit to be plugged into a wall
receptacle.
Use two conductor, non-metallic
sheath cable with ground wire
(3 wires total) for the incoming
power supply.
CAUTION: Use the
WHITE - N
BLACK – L1
GROUND - G
10
appropriate wire to meet local
and national electrical codes
for rated power consumption.
• Cut the wire to an appropriate
length.
• Connect the L wire from the
unit to the live wire
main power through the
wall switch, ensuring all live
connections are connected
with a wire nut.
• Connect the N wire from the
unit to the neutral wire from
the power supply with a wire
nut.
• Connect the G wire from the
unit to the ground wire from
the power supply with a wire
nut or attach the grounding
wire to the cover with the
provided grounding screw, by
placing the wire in-between
WALL
SWITCH
WHITE – N
BLACK – L1
GROUND - G
www.dimplex.com
from the
120 V
POWER
SUPPLY
(BREAKER
PANEL)