4. Close the HP and LP valves on the display and
control panel.
5. Switch off ACS 810.
6. Disconnect ACS 810 from power supply.
7. Carefully open the ACS 810 housing.
8. Carefully remove the old Combo filter.
9. Insert the new Combo filter with the new sealing
rings and ensure correct positioning of the sealing
rings.
Fig. 5:
Combo filter
10. Close the housing.
"
The filter is replaced.
i
Return with <Stop>.
Robert Bosch GmbH
Component test and maintenance | ACS 810 | 29 |
12.6.2

Reset filter

!
Observe the ACS 810 menu prompting.
1. Call up start screen.
2. Press <3> and <Flush> simultaneously and release.
 The message
ENTER CODE 0000
5555
and confirm with E.
3. Enter code
4. Select "CHANGE FILTER" with o u and confirm
with E.
 The current quantity (in kg) of filtered refriger-
ant is displayed.
5. Press <MENU> until filtered refrigerant quantity is
reset to zero.
"
Filter change interval is reset.
i
Return with <Stop>.
en
is displayed.
|
1 689 975 253