Non-Condensing Gases - Bosch ACS 810 Repair Instructions

A/c service unit
Hide thumbs Also See for ACS 810:
Table of Contents

Advertisement

8.9

Non-condensing gases

i
The drain valve (V6) for non-condensing gases
opens if the pressure in the refrigerant cylinder
is higher than the set opening pressure (normally
between 12 and 14 bar).
M2
HIGH
T2
M1
LOW
T1
F2
6
C
Des. Description
1
Fresh oil tank
2
Vacuum pump
3
Expansion valve
4
Evaporator/oil separator
5
Compressor oil separator
6
Compressor
7
Internal refrigerant cylinder
8
Refrigerant cylinder scale
9
Used oil bottle
10
Heat exchanger
11
Refrigerant pump
T1
Low pressure hose
T2
High pressure hose
M1
Low pressure gage
M2
High pressure gage
M3
Internal refrigerant cylinder pressure gage
F1
Coarse filter
Robert Bosch GmbH
EV10
P
11
P2
HP
5
4
10
EV7
9
Service phases | ACS 810 | 21 |
i
The pressure of the internal refrigerant cylinder
increases during the recovery phase and when
preparing the refrigerant.
i
The safety valve (V5) opens at a factory set
pressure (approx. 18 bar) to limit the pressure in
the internal refrigerant cylinder.
P1
EV1
EV8
VU1
1
3
F1
V5
V1
V3
8
Des. Description
F2
Combi filter
VU1
Oil non-return valve
EV1
Vacuum solenoid valve
EV3
Flow solenoid valve
EV5
Recovery solenoid valve
EV6
Filling solenoid valve
EV7
Oil drain solenoid valve
EV8
Oil injection solenoid valve
EV10 Refrigerant pump by-pass solenoid valve
P1
Pressure sensor
P2
Pressure switch
V1
Tank vapour side hose valve
V2
Tank liquid side hose valve
V3
Tank vapour side valve
V4
Tank liquid side valve
V5
Safety valve
V6
Non condensable drain valve
EV3
EV5
EV6
2
P
V6
V4
V2
7
|
1 689 975 253
2021-01-26
en
M3

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents