13H : number of DLT2 accesses exceeded
19H : max. number of DECT base stations exceeded
21h : B channel init failed
22h : max. number of analog trunks reached for a cabinet
23h : max. number of analog trunks reached for the system
24h : maximum of resources reached
1CH : exceeded equipment level in module in terms of available energy
1DH : exceeded max. number of HSL resources in a module
1EH : exceeded max. number of HDLC resources for the overall system
1FH : exceeding max number of analogue lines in a module (RackX)
20H : exceeding the max number of analogue lines in the system
6.5.5
Additional information contained in message 112 (INFO 1: type of error)
This message only concerns the Reflexes stations.
60h : unequipped station
61h : transmission of erroneous message
62h : bad checksum message
63h : occupation of UA link
64h : receipt of a reset
65h : out of order option dedicated handset
66h : unplugging of the handset
67h : maintenance seized handset
6.5.6
Types of interface (INFO 0 of message 113)
01H : analog set interface
03H : T0 access interface
04H : T2 access interface
05h : S0 set interface
14H : Reflexes set interface
1Dh : "integrated voice mail" interface
20H : master DECT base interface
21H : slave DECT base interface
22H : DECT Reflexes interface
25H : Multi Reflexes interface
26H : IP interface
27h : IP network interface