Operating Limits

The table that follows provides the operating limits that have to be followed to
ensure a correct operation of the air conditioner.
Maximum requirements (2)
COOL
DEHUMIDIFICATION
(1)
Minimum requirements
Maximum requirements (2)
HEATING
(1)
Minimum requirements
Single-phase rated voltage
POWER SUPPLY
Minimum and maximum
limit
b.s.: Dry bulb - b.u.: wet bulb;
(1) As per standard UNI EN 14511
(2) Maximum relative humidity: 80% or lower
 The standardized temperature for heating is 7°C. If the outdoor temperature drops
to 0°C or below, the heating capacity can be reduced depending on the temperature
condition.
If the cooling operation is used at over 32°C(indoor temperature), it does not cool at
its full capacity.
 The use of the air conditioner at a relative humidity above the expected one (80%)
may cause the formation of condensate and the leakage of water drops on the floor.
Outdoor temperature: 50°C(Differ according to model)
Indoor temperature: 32°C b.s. / 23°C b.u.
Outdoor temperature: –15°C
Indoor temperature: 21°C b.s. / 15°C b.u.
Outdoor temperature: 24°C b.s. / 18°C b.u.
Indoor temperature: 27°C b.s.
Outdoor temperature: -20°C b.s.
Indoor temperature: 15°C
220V-240V ~ 50Hz
198V min. - 264V max.
13