1. REMOVAL OF MECHANICAL PARTS
AND P.C. BOARDS
CAUTION
Be careful not to remove the FFC cable forcibly, because
the FFC cable may be damaged.
1-1: STAND ASS'Y (Refer to Fig. 1-1)
1. Remove the 4 screws (1).
2. Remove the Stand Ass'y in the direction of arrow.
Back Cabi Ass'y
1-2: BACK CABI ASS'Y/REMOCON PCB/OPERATION PCB
(Refer to Fig. 1-2)
1. Remove the 5 screws (1).
2. Remove the Cover Jack Ass'y in the direction of arrow (A).
3. Remove the 27 screws (2).
4. Remove the Back Cabi Ass'y in the direction of arrow (B).
5. Disconnect the following connectors: (CP2201, CP2202).
6. Remove the screw (3).
7. Remove the Remocon PCB in the direction of arrow (C).
8. Remove the 2 screws (4).
9. Remove the Operation PCB in the direction of arrow (D).

DISASSEMBLY INSTRUCTIONS

Stand Ass'y
(1)
(1)
(1)
(1)
Fig. 1-1
Back Cabi Ass'y
(2)
(2)
(2)
(2)
(2)
(2)
1-3: MAIN UNIT (Refer to Fig. 1-3)
1. Remove the screw (1).
2. Remove the 4 screws (2).
3. Disconnect the following connectors:
(CP3806, CN12, CN18).
4. Remove Plate Jack in the direction of arrow (A).
5. Remove the Main Unit in the direction of arrow (B).
B1-1
(1)
(1)
(1) (1)
(1)
Cover Jack Ass'y
(2)
(A)
(2)
(2)
(2)
(2)
(2)
(2)
(2)
(2)
(2)
(C)
(2)
Remocon PCB
(3)
(B)
Operation PCB
(2)
(2)
(2)
(2)
Main Unit
(A)
(1)
(B)
(2)
(2)
(2)
(D)
(4) (4)
Fig. 1-2
Plate Jack
Fig. 1-3

Advertisement