Instructions To Our Customer / End User; Service; Control Diagnostics - Thermo Pride OD6FA072D48 Installation, Operation And Service Manual

Oil-fired central furnace
Table of Contents

Advertisement

Instructions to Our Customer / End User

! WARNING: If the burner does not operate properly after depressing the oil
primary reset button, turn off the electrical power to the furnace and close the
manual oil shutoff valve. Immediately contact a qualified heating contractor for

service.

Before leaving a new installation, the installer should show the customer or end user
where the furnace instruction manual is kept. He should also discuss the following points:
1) Describe the general operation of the furnace and, if properly equipped, the
cooling system.
2) Show the location of the furnace air filter(s) and those in the duct system, if
equipped. Demonstrate how to remove, clean, and replace the air filter(s).
3) Demonstrate how to set and adjust the room air temperature using the room
thermostat.
4) Demonstrate how to operate (turn on and off), the heating system and, if properly
equipped, the cooling system and the circulating air blower.
5) Show the location of the oil primary safety control in the furnace. Describe when
and demonstrate how to depress the oil primary reset button.
SERVICE

Control Diagnostics

The control boards are equipped Input Status LEDs. These are intended to provide a
quick view into furnace performance without requiring a voltmeter.
UT Control
 Normal Operation Indicators
Thermostat Inputs: Green LEDs indicate 24V signal present at terminal.
Status: Red LED is on solid to indicate valid input signal. In Standby Red
LED is off.
 Fault LED Indicator
Limit: Red LED will flash rapidly while 120VAC is missing from the limit
switch.
NRG Max Control
 Normal Operation Indicators
Thermostat Inputs: Amber LEDs indicate 24V signal present at terminal
Status: Blue LED pulses at various speeds to indicate operational state
24V Transformer: Green LED indicates that 24V transformer is powered
Blower: Green LED indicates Blower Relay is energized
Burner: Green LED indicates Burner TT Relay is energized
 Fault LED Indicator
Limit: Red LED indicates that High Limit is Open
21