MAINTENANCE
The battery charger does not need any maintenance. To ensure optimum performance from the equipment, once a
year check the cables and the electrical connections.
TECHNICAL DATA
MODEL
OUTPUT CHARACTERISTICS
Maximum output current
(1)
Charge absorption voltage
Charge float voltage
DC absorption from the batteries
Residual ripple
(3)
Charging characteristics
Number of outputs
(4)
INPUT CHARACTERISTICS
Supply voltage
Frequency
Maximum absorption
(230/240 Vac)
(5)
Maximum absorption (120 Vac)
Power factor (cos ϕ )
(5)
Efficiency
(5)
PROTECTION
Reverse polarity
(7)
Overload
Output short circuit
Overvoltage in output
(8)
Overheating
Battery overtemperature
AMBIENT CHARACTERISTICS
Operating temperature
Cooling
Noisiness (acoustic)
Humidity
CASE
Material
Dimensions (WxHxD)
Weight
GENERAL
CAN BUS interface
Charge compensation
Safety standard
EMC Standard
Maximum rated value at normal use or in short circuit.
(1)
(2)
With battery charger not supplied by the AC network and with disabled monitor mode.
(3)
At 50% of the output current on resistive load.
(4)
Each output can supply the maximum value of nominal current. The sum of the currents supplied from each output can not exceed the maxi-
mum nominal value of the equipment.
With supply voltage equal to 230 Vac and output current equal to the maximum nominal value.
(5)
With supply voltage equal to 120 Vac and output current equal to the maximum nominal value.
(6)
Protection may be inefficient in some operative conditions.
(7)
(8)
Software/hardware double-check.
Cycoloy
®
is a registered trade mark of GE Plastics.
QUICK
®
RESERVES THE RIGHT TO MODIFY THE TECHNICAL CHARACTERISTICS OF THE EQUIPMENT AND THE CONTENTS OF THIS MANUAL WITHOUT PRIOR NOTICE.
SBC NRG HIGH POWER - REV001A

MAINTENANCE - TECHNICAL DATA

SBC 1200 NRG FR
(
)
100 A
14,1 Vdc EL open
14,4 Vdc EL sealed / Gel / AGM
13,4 Vdc EL open
13,8 Vdc EL sealed / Gel
13,6 Vdc AGM
(2)
< 3,5 mA
264÷83 Vac, with power
reduction under 108 Vac
6,7 A
(6)
13,1 A
≥ 88%
SBC 1450 NRG HR
(
)
60 A
28,8 Vdc EL sealed / Gel / AGM
27,6 Vdc EL sealed Gel - 27,2 Vdc AGM
< 100 mV RMS
Automatic in three stages IUoU
3
with power reduction under 207 Vac
45÷66 Hz
7,9 A
1,00
Yes, through fuse
Yes
Yes
Yes
Yes
Yes, optional
-15 ÷ +70 °C, with linear power reduction over +50 °C
Quick Smart Fan (Forced, with variable fans speed)
< 51 dbA @ 1 m (42 dbA @ 1 m in silent mode)
Max. 95% RV without condensation
Aluminium - Cycoloy
243 x 557 x 116 mm
6,9 kg
Yes
Yes, optional (max 128 battery temperature sensors)
EN 60335-2-29
EN 55022/B - FCC TITLE 47 PART 15 SUBPART B CLASS B
SBC 1950 NRG HR
SBC 2450 NRG HR
(
)
80 A
100 A
28,2 Vdc EL open
26,8 Vdc EL open
< 5 mA
264÷161 Vac,
10,5 A
-
≥ 92%
®
GB
(
)
12,9 A
35