EQUIPMENT NECESSARY FOR INSTALLATION
Depending upon model, use the batteries and cables on the output terminals as specified in the following table:
MODEL
Battery voltage
Battery capacity
Minimum output cable size
Number of battery cells
MODEL
Battery voltage
Battery capacity
Minimum output cable size
(battery charger-junction "J")
Minimum output cable size
(junction "J" - battery)
Number of battery cells
MODEL
Battery voltage
Battery capacity
Minimum output cable size
(battery charger-junction "J")
Minimum output cable size
(junction "J" - battery)
Number of battery cells
For the single battery chargers, the wires connected to the output terminals must have a maximum length of 4 meters.
For the length of the output wires in case more battery chargers are connected in parallel (current sharing mode) refer to the
diagram of Fig. 2B.
WARNING: the battery charger must be used only with re-chargeable lead/liquid electrolytic batteries (open or
sealed), GEL, AGM.
WARNING: the battery charger can not be used to recharge non rechargeable batteries.

INSTALLATION SITE

Install the battery charger as close as possible to the batteries in a
dry and airy spot, to allow the correct operation of the device at full
power.
The battery charger can be installed in a horizontal or vertical position
with cables coming out in the downward position.
In case of battery chargers connected in parallel (current sharing mo-
de), installing one next to the other.
The battery charger must be fixed to the support surface with screws
strong enough to support its weight, paying attention that they do not
weaken or cause cracks to the boat structure.
The vertical position is recommended because the natural convection of
heat helps to cool the equipment.
The perimeter of the battery charger (excluding the support base) must
be kept at a distance from walls or objects by a minimum of 5 cm.
SBC NRG HIGH POWER - REV001A
CHARACTERISTICS AND INSTALLATION
SBC 1200 NRG FR
SBC 1450 NRG HR
12 V
450 ÷ 1000 Ah
50 mm
2
6
SBC 700 NRG FR
SBC 1100 NRG FR
2 units in parallel
2 units in parallel
12 V
900 ÷ 2000 Ah
540 ÷ 1200 Ah
50 mm
2
95 mm
2
6
SBC 700 NRG FR
SBC 1100 NRG FR
3 units in parallel
3 units in parallel
12 V
1350 ÷ 3000 Ah
810 ÷ 1800 Ah
50 mm
2
150 mm
2
6
SBC 1950 NRG HR
270 ÷ 600 Ah
360 ÷ 800 Ah
25 mm
2
SBC 1950 NRG HR
2 units in parallel
720 ÷ 1600 Ah
25 mm
2
50 mm
2
SBC 1950 NRG HR
3 units in parallel
1080 ÷ 2400 Ah
25 mm
2
95 mm
2
SBC 2450 NRG HR
24 V
450 ÷ 1000 Ah
35 mm
2
50 mm
12
SBC 2450 NRG HR
2 units in parallel
24 V
900 ÷ 2000 Ah
35 mm
2
50 mm
70 mm
2
95 mm
12
SBC 2450 NRG HR
3 units in parallel
24 V
1350 ÷ 3000 Ah
35 mm
2
50 mm
120 mm
2
150 mm
12
5 cm
5 cm
5 cm