Warning Messages; Status Messages - Quick SBC NRG Series Manual Of Installation And Use

Hide thumbs Also See for SBC NRG Series:
Table of Contents

Advertisement

Available languages

Available languages

NOTIFICATION SIGNS
GB

WARNING MESSAGES

COD.
MESSAGE
61
Batt M lo
62
Batt M hi
63
Batt 1 lo
64
Batt 1 hi
65
Batt 2 lo
66
Batt 2 hi

STATUS MESSAGES

COD.
MESSAGE
71
BULK
72
ABSORPTION
73
FLOAT
74
Derating
75
76
Monitor
77
Limit power
78
Silent mode
79
Sharing on
80
Charge comp
34
DESCRIPTION
The battery's or battery bank's voltage, measured on the MASTER output terminal, is lower than 11 Vdc
(mod. SBC 1200 NRG FR) or 22 Vdc (mod. SBC 1450 NRG HR, SBC 1950 NRG HR, SBC 2450 NRG HR).
As soon as the voltage goes back to a higher/equal value to 11 Vdc, the notification disappears
(mod. SBC 1200 NRG FR) or 22 Vdc (mod. SBC 1450 NRG HR, SBC 1950 NRG HR, SBC 2450 NRG HR).
The battery's or battery bank's voltage, measured on the MASTER output terminal, is higher than 14,8 Vdc
(mod. SBC 1200 NRG FR) or 29,6 Vdc (mod. SBC 1450 NRG HR, SBC 1950 NRG HR, SBC 2450 NRG HR).
As soon as the voltage goes back to a lower/equal value to 14,8 Vdc, the notification disappears
(mod. SBC 1200 NRG FR) or 29,6 Vdc (mod. SBC 1450 NRG HR, SBC 1950 NRG HR, SBC 2450 NRG HR).
The battery's or battery bank's voltage, measured on the SLAVE1 output terminal, is lower than 11 Vdc
(mod. SBC 1200 NRG FR) or 22 Vdc (mod. SBC 1450 NRG HR, SBC 1950 NRG HR, SBC 2450 NRG HR).
As soon as the voltage goes back to a higher/equal value to 11 Vdc, the notification disappears
(mod. SBC 1200 NRG FR) or 22 Vdc (mod. SBC 1450 NRG HR, SBC 1950 NRG HR, SBC 2450 NRG HR).
The battery's or battery bank's voltage, measured on the SLAVE1 output terminal, is higher than 14,8 Vdc
(mod. SBC 1200 NRG FR) or 29,6 Vdc (mod. SBC 1450 NRG HR, SBC 1950 NRG HR, SBC 2450 NRG HR).
As soon as the voltage goes back to a lower/equal value to 14,8 Vdc, the notification disappears
(mod. SBC 1200 NRG FR) or 29,6 Vdc (mod. SBC 1450 NRG HR, SBC 1950 NRG HR, SBC 2450 NRG HR).
The battery's or battery bank's voltage, measured on the SLAVE2 output terminal, is lower than 11 Vdc
(mod. SBC 1200 NRG FR) or 22 Vdc (mod. SBC 1450 NRG HR, SBC 1950 NRG HR, SBC 2450 NRG HR).
As soon as the voltage goes back to a higher/equal value to 11 Vdc, the notification disappears
(mod. SBC 1200 NRG FR) or 22 Vdc (mod. SBC 1450 NRG HR, SBC 1950 NRG HR, SBC 2450 NRG HR).
The battery's or battery bank's voltage, measured on the SLAVE2 output terminal, is higher than 14,8 Vdc
(mod. SBC 1200 NRG FR) or 29,6 Vdc (mod. SBC 1450 NRG HR, SBC 1950 NRG HR, SBC 2450 NRG HR).
As soon as the voltage goes back to a lower/equal value to 14,8 Vdc, the notification disappears
(mod. SBC 1200 NRG FR) or 29,6 Vdc (mod. SBC 1450 NRG HR, SBC 1950 NRG HR, SBC 2450 NRG HR).
DESCRIPTION
The battery charger is in the BULK phase.
(See paragraph "OPERATION - Charging characteristics").
The battery charger is in the ABSORPTION phase.
(See paragraph "OPERATION - Charging characteristics")
The battery charger is in the FLOAT phase.
(See paragraph "OPERATION - Charging characteristics")
The battery charger performs a limitation on the maximum output current due to a thermal problem, due a fan
which is not working or due low AC voltage.
Signal not expected in this model.
The battery charger is in monitor mode
(See paragraph "BATTERY CHARGER PROGRAMMING-Secondary menu-monitor mode").
The manual mode of the maximum output current reduction has been activated.
(See paragraph "BATTERY CHARGER PROGRAMMING-Secondary menu-maximum output current").
The silent mode for the cooling fans has been activated.
(See paragraph "BATTERY CHARGER PROGRAMMING-Secondary menu-silent mode").
The battery charger is carrying out the current sharing with 2 or 3 battery chargers connected in parallel.
The battery charger is carrying out the batteries' charge compensation according to their temperature.
Active only if the KTB4'S interface with the relevant sensor (not supplied) is connected to the system.